Connecting to the Battery

Connecting to the Battery
To simplify the connection process it is advised to connect the battery to the inverter   b efore mounting 
the battery according to the manufacturer instructions.
Follow these guidelines: 
 
For easy access to battery connectors, it is recommended to connect the cables to the battery and 
l
to set all the battery DIP switches to their correct positions while the battery is still on the ground,  
before mounting the battery according to the manufacturer instructions). The following procedure is 
recommended:
 a.  Connect all the wires to the battery connection panel
 b.  Mount the battery
 c.  Assemble the conduit between the battery and the inverter
 d.  Connect to the Connection Unit.
 
Measure the necessary length between the Connection Unit and the battery for all cables. The 
l
maximum distance between the battery and the inverter is 35 ft/ 10 m, when using  24 AWG/ 0.2 mm
cables for battery control.
 
Tie and wrap the cables   t o avoid pulling them out during mounting.
l
 
Be sure to adhere to all safety cautions and information in the battery documentation. 
l
 
The battery   c onnects to the DC side of the inverter. Since the inverter DC connections are on its left 
l
side, it is recommended to position the battery   t o the left of the inverter to simplify wiring.
WARNING!
The battery should be powered OFF before and during wiring. Turn OFF:
The auxiliary power supply switch
l
The circuit breaker switch
l
La batterie doit être étteinte avant et pendant le câblage. Fermer: 
 
Le commutateur d'alimentation auxiliaire 
 
l
 
Le commutateur du coupeur 
l
 