Relay State Information
When one or both relays are enabled, the relay state (active/not active) is shown on the
optional display. You can also check the status of the relays in the Status view of the wireless
configuration interface.
Figure 20 Relay Icons on the Optional Display (Relay A Active, Relay B Not Active)
Relay Activation Setpoint and Hysteresis
You can define whether the relay is activated when the measurement falls below a set limit
(Active below trigger level), or when the measurement exceeds a set limit (Active above
trigger level). To prevent the relay switching back and forth when the measured value is
near to the setpoint value, you can set a hysteresis with the Low Trigger Level and High
Trigger Level settings.
For example, if you want the relay to activate when the measurement exceeds (Active
above trigger level) 2000 units, but do not want the relay to switch off if the measurement
momentarily falls between 2000 and 1980 units, set the High Trigger Level to 2000 and
Low Trigger Level to 1980. With this configuration, the relay activates when the
measurement exceeds 2000, but does not switch off until the measurement falls below
1980.
6.2 Setting Relay Activation Limit
Without Hysteresis
You can set the relay to activate when the probe measurement exceeds or falls below a set
limit. When you configure a single setpoint for relay activation without hysteresis, the relay
switches on or off immediately when the measurement moves over or below the setpoint
(depending on the low/high activation mode selection).
When you enter a value into a field, the value is saved automatically when you exit the
input field (for example, tap on an area outside of the field).