3.22 TECHNICAL PARAMETERS FOR COMBINATION BOILERS IN COMPLIANCE WITH REGULATION 813/2013 .

E ciencies in the following tables refer to the gross calori c value.
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and combination boilers: useful heat output
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load pro le
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera-
ture.
3.23 PRODUCT FICHE IN COMPLIANCE WITH REGULATION 811/2013 .
VICTRIX EXA 24 X 1 ErP
++
A
+
A
A
B
C
D
E
F
G
24
51
dB
Victrix EXA 24 X 1 ErP
SI
NO
NO
NO
NO
Symbol
Value
Unit
P
24
kW
n
P
23.7
kW
4
P
7.1
kW
1
el
0.039
kW
max
el
0.019
kW
min
P
0.006
kW
SB
Q
kWh
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
Annual energy consumption for the heating function (Q
Annual electricity consumption for the domestic hot water function
(AEC)
Annual fuel consumption for the domestic hot water function (AFC)
Seasonal space heating energy e ciency (η
Water heating energy e ciency ( η
For proper installation of the appliance refer to chapter 1 of this booklet (for the in-
staller) and current installation regulations. For proper maintenance refer to chapter
A
3 of this booklet (for the maintenance technician) and adhere to the frequencies and
methods set out herein.
kW
35
Fitted with supplementary heating system:
Element
Seasonal energy e ciency of central
heating
For central heating only and combination boilers: useful e ciency
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Other items
Heat loss in standby
Ignition burner energy consumption
Emissions of nitrogen oxides
Domestic hot water production e ciency
Daily gas consumption
Parameter
)
wh
NO
Symbol
Value
Unit
η
92
s
η
88.4
4
η
97.0
1
P
0.078
kW
stby
P
0.000
kW
ign
mg /
NO
40
kWh
X
η
WH
Q
kWh
fuel
value
)
74.4 GJ
HE
---
---
)
92 %
s
---
%
%
%
%