From this moment the boiler functions automati-
cally. With no demand for heat (central heating
or domestic hot water production) the boiler
goes to "standby" function, equivalent to the
boiler being powered without presence of ame.
Each time the burner ignites, the relative ame
present symbol is displayed (10) with relative
output scale.
• Operation with Comando Amico Remoto
(CAR
V2
) (Optional). If the CAR
V2
the (
) symbol will appear on the display.
e boiler regulation parameters can be set via
the CAR
V2
control panel and the reset button
(3) remains active on the boiler control panel,
along with the switch-off button (1) ("off "
mode only) and the display where the function-
ing state is shown.
Caution: if the boiler is switched "o " the
CAR
V2
will display the connection error symbol
"ERR>CM", the CAR
V2
is however powered
constantly so as not to lose the stored programs.
• Solar operating mode (
).
cannot be activated on this boiler model.
• Operation with optional external probe
(
). In the case of a system with optional
external probe, the boiler ow temperature
for room central heating is managed by the
external probe depending on the external
temperature measured (Par. 1.8). The flow
temperature can be modi ed by selecting the
functioning curve via the selector switch (6)
Error
Anomaly signalled
Code
No ignition block
01
Safety thermostat
block
02
(over-temperature)
Flue safety
03
thermostat block
Contacts resistance
04
block
Flow probe
05
anomaly
Maximum N° of
08
reset
Insu cient system
10
pressure
Storage tank probe
12
anomaly (optional)
15
Con guration error
Fan anomaly
16
Parasite ame
20
block
Return probe
23
anomaly
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Technical A er-Sales Service).
(or on the CAR
to the boiler) selecting a value from "0 to 9".
With external probe present, the relative
symbol (18) will appear on the display. In the
central heating phase, if the temperature of the
water contained in the system is su cient to
heat the radiators, the boiler can only function
with the activation of the pump.
V2
• "Stand-by" mode. Press button (1) repeatedly
is connected,
until the symbol (
the boiler remains inactive and the antifreeze
function, pump anti-block function and 3-way
and signalling of any anomalies is guaranteed.
N.B.: in these conditions the boiler is still
powered.
• "O " mode. By holding the button (1) down
for 8 seconds, the display switches-o and the
boiler is o completely.
not guaranteed in this mode.
IMPORTANT NOTE: in these conditions the
boiler is considered still live even if there are
is function
no functions active.
• "Automatic vent" mode. Every time the boiler
is electrically powered, the system automatic
vent function is activated (lasting 8 minutes).
is function is displayed via a countdown
signalled by the indicator (14). During this
period the DHW and CH functions are not
active.
e "automatic vent" can be annulled by press-
ing the "reset" button (4).
Cause
In the event of request of room central heating or domestic hot water
production, the boiler does not switch on within the preset time. Upon
appliance commissioning or a er extended downtime, it may be neces-
sary to eliminate the block.
During normal operation, if a fault causes excessive overheating internally,
the boiler goes into overheating block.
During normal operation, if a fault causes excessive ue gas overheating,
the boiler blocks
e P.C.B. detects an anomaly on the gas valve supply. Check the connec-
tion. (the anomaly is detected and displayed only in the event of a request).
e board detects an anomaly on the ow NTC probe.
Number of allowed resets that have already performed.
Water pressure inside the central heating circuit that is su cient to guar-
antee the correct operation of the boiler is not detected.
If the board detects an anomaly on the boiler probe, the boiler cannot
produce domestic hot water (when the boiler is connected to an external
storage tank unit) and signals an anomaly.
If the board detects an anomaly or incongruity on the electric wiring, the
boiler will not start.
is occurs if the fan has a mechanical or electrical fault.
is occurs in the event of a leak on the detection circuit or anomaly in
the ame control unit.
e board detects an anomaly on the return NTC probe.
V2
control panel, if connected
) appears. From now on
e safety functions are
22
• Display operation.
e display lights up during
the use of the control panel, a er 15 seconds
inactivity, the brightness drops until just the
active symbols are displayed.
e lighting mode
can be varied via parameter T3 in the P.C.B.
customisation menu.

2.5 TROUBLESHOOTING.

e Victrix EXA 24 X 1 ErP boiler reports any
anomalies using a code shown on the boiler
display (14), listed in the table below:
On the remote control, the error code will be
displayed by means of the same numeric code
represented according to the following example
V2
(e.g. CAR
= Exx).
Boiler status / Solution
Press the Reset button (1).
Press the Reset button (1).
Press the Reset button (1).
e boiler does not start (1).
e boiler does not start (1).
Attention: the anomaly can be reset 5 times
consecutively, a er which the function in
inhibited for at least one hour. One attempt
is gained every hour for a maximum of 5
attempts. By switching the appliance on and
o the 5 attempts are re-acquired.
Check on the boiler pressure gauge (1) that
the system pressure is between 1÷1.2 bar
and restore the correct pressure if necessary.
e boiler does not satisfy the DHW pro-
duction requests (1).
If normal conditions are restored the boiler
restarts without having to be reset. Check
that the boiler is con gured correctly (1).
Press the Reset button (1).
Press the Reset button (1).
e boiler does not start (1).