1.11 OUTDOOR INSTALLATION IN A
PARTIALLY PROTECTED AREA.
N.B.: a partially protected location is one in which
the appliance is not exposed to the direct action of
the weather (rain, snow, hail, etc..).
is type of installation is only possible when
permitted by the laws in force in the appliance's
country of destination.
• Con guration type B, open chamber and
forced draught.
Using the special coverage kit one can achieve
direct air intake (Fig. 1-9) and fumes exhaust in
a single ue or directly outside. In this con gura-
tion it is possible to install the boiler in a partially
protected place. In this con guration the boiler
is classi ed as type B.
With this con guration:
- air intake takes place directly from the envi-
ronment in which the appliance is installed
(outside);
- the fumes exhaust must be connected to its own
single ue (B23) or ducted directly outside via
a vertical terminal for direct exhaust (B
via an Immergas ducting system (B
The technical regulations in force must be
respected.
• Coverage kit assembly (Fig. 1-10). Remove
the two plugs and the gaskets present from
the two lateral holes with respect to the central
one. Now cover the right intake hole using the
relevant plate, xing it onto the le side using
the 2 previously-removed screws. Install the
Ø 80 outlet ange on the central hole of the
boiler, taking care to insert the gasket supplied
with the kit and tighten by means of the screws
e cover kit includes:
N° 1
ermoformed cover
N°1
Gasket clamping plate
N°1
Gasket
N°1
Gasket tightening strap
N°1
Intake hole covering plate
e terminal kit includes:
N° 1
Gasket
N° 1
Discharge ange Ø 80
N° 1
Bend 90° Ø 80
N° 1
Drain pipe Ø 80
N° 1
Wall sealing plate
provided. Install the upper cover, xing it using
the 4 screws present in the kit, positioning the
relevant gaskets. Engage the 90° Ø 80 bend
with the male end (smooth) in the female end
(with lip seal) of the Ø 80 ange unit until it
stops. Introduce the gasket, making it run along
the bend. Fix it using the sheet steel plate and
tighten by means of the straps present in the
kit, making sure to block the 4 gasket aps. Fit
the male end (smooth) of the exhaust terminal
into the the female end of the bend 90° Ø 80,
making sure that the relevant wall sealing plate
is already tted; this will ensure hold and join-
ing of the elements making up the kit.
Max. length of exhaust duct.
vertical or horizontal) can be extended to a max.
length of 30 linear metres.
• Coupling of extension pipes. To install any
push- t extensions with other ue elements,
it is necessary to act as follows: install the pipe
or elbow with the male side (smooth) into the
female section (with lip seal) to the end stop
on the previously installed element.
) or
ensure correct sealing and joining of the ele-
53
).
ments.
53
• Con guration without cover kit in a partially
protected location (type C boiler)
By leaving the side plugs tted it is possible
to install the appliance externally without the
cover kit. Installation takes place using the
Ø60/100, Ø 80/125 and separator Ø 80/80
concentric intake/ exhaust kits. Refer to the
paragraph relative to indoor installation. In
this con guration the upper cover kit guaran-
tees additional protection for the boiler. It is
recommended but not compulsory.
e ue pipe (both
is will
1-10
11
1-9
1-11