Immergas UB INOX SOLAR 200 ERP Instruction And Recommendation Booklet

Hide thumbs Also See for UB INOX SOLAR 200 ERP:

Advertisement

Quick Links

UB INOX SOLAR
Instruction and
IE
recommendation booklet
200 ERP
Storage tank unit

Advertisement

Table of Contents
loading

Summary of Contents for Immergas UB INOX SOLAR 200 ERP

  • Page 1 UB INOX SOLAR Instruction and recommendation booklet 200 ERP Storage tank unit...
  • Page 3 Dear Customer, Our compliments for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas customer you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your storage tank unit.
  • Page 4: Table Of Contents

    INDEX INSTALLER page USER page MAINTENANCE TECHNICIAN page Storage tank unit installation ....5 Use and maintenance instructions ..14 Checks and maintenance ......15 1.1 Installation recommendations....5 2.1 Cleaning and maintenance....14 3.1 Hydraulic diagram........15 1.2 Main dimensions........5 2.2 Emptying the storage tank unit.
  • Page 5: Storage Tank Unit Installation

    The place of installation of the appliance and authorised company (e.g. the Authorised Tech- relative Immergas accessories must have suitable nical Assistance centre, which has specifically features (technical and structural) such to allow trained staff and original spare parts).
  • Page 6: Connection Unit

    - press the “i” key for about 2 seconds. Attention: Immergas S.p.A. declines any respon- cally controls the temperature of the mixed water - upon accessing parameter 27, you will find that sibility for damage or physical injury caused by set by the user.
  • Page 7: Storage Tank Unit Hydraulic Circuit

    (Fig. 1-3). In order to connect the storage tank unit to Immergas boilers properly, refer to the boiler instruction book. 1.10 MAIN SOLAR CIRCULATION UNIT COMPONENTS.
  • Page 8: Circulation Pump (Solar Heating System)

    1.11 CIRCULATION PUMP (SOLAR Selection of operating mode. To see the current necessary to press button (1) longer than 10 HEATING SYSTEM). operation mode it is sufficient to press button seconds (during which the current configuration The units are supplied with circulating pumps (1) once.
  • Page 9: Commissioning

    UB INOX SOLAR 200 ErP storage tank, with prevent air circulating inside the circuit. sufficient capacity to perform this task.
  • Page 10: Solar Control Unit User Instructions

    6 Eliminate any air in the solar circuit preferably 9 Set the functioning pressure in the circuit at Do not fill the system in conditions with strong 2.0 bar + 0.1 bar for every metre in the distance using the so-called "pressure shot" method, insolation and with the manifolds at high which consists in raising the filling pressure of between the solar collector and the expansion...
  • Page 11 List and description of parameters available. The board has 34 parameters. The parameters that go from 1 to 11 is simple information and cannot be modified. N° Description of the Parameter Values Field Default Parameter Software Version 1÷99 Current temperature S1: NTC sensor (°C) 0÷120 Current temperature S2: NTC sensor (°C) 0÷120...
  • Page 12 • Use and operation. - Priority solar function. The function is ac- - Solar pump functioning. tive when: - Start-up display. The pump activates and deactivates automati- DHW inhibition probe T (PAR 31 - PAR 33) cally when it is set in On/Off mode. Every time power is supplied to the appliance, <...
  • Page 13: Main Components

    1.16 KITS AVAILABLE ON REQUEST. • Recirculation kit (on request). The storage tank unit is prepared for application of the pump kit. Immergas supplies a series of fittings and attachments that allow connection between the storage tank unit and domestic hot water system.
  • Page 14: Use And Maintenance Instructions

    “annual check and maintenance of the instructions. appliance”, in compliance with national, regional, or local standards in force. Annual maintenance is essential to validate the Immergas warranty. We recommend stipulating a yearly cleaning and maintenance contract with an authorised local firm.
  • Page 15: Checks And Maintenance

    CHECKS AND MAINTENANCE 3.1 HYDRAULIC DIAGRAM. Key: 16 - Solar expansion vessel 1 - Storage tank unit draining valve 17 - Solar pump 2 - 8 bar safety valve 18 - Flow meter 3 - Magnesium anode 19 - Domestic hot water probe 4 - D.H.W.
  • Page 16: Wiring Diagram

    3.2 WIRING DIAGRAM. Key: 1 - Supply voltage 230 Vac 50 Hz A12 - Solar management control unit 2 - Boiler clamps 36 and 37 B2 - Domestic hot water probe (NTC) 3 - Domestic hot water integration B11 - Solar manifold probe (PT1000) 4 - Black B12 - Solar storage tank probe (NTC) 5 - White...
  • Page 17: Removing The Casing

    3.4 REMOVING THE CASING. To facilitate storage tank maintenance, the casing can be completely removed as follows: IMPORTANT NOTE: the procedure for remov- ing the casing is the same for all storage tank unit models. - remove the lid (1) by pulling it upwards; - undo the screws (2) and pull the front panel outwards (3);...
  • Page 18: Technical Specifications

    3.6 TECHNICAL SPECIFICATIONS. Storage tank useful capacity Domestic hot water side maximum pressure DHW side maximum temperature °C Domestic hot water expansion vessel total volume Dispersions kW/24h 3.42 Psbsol 3.17 Coil thickness Solar coil length 6500 CH coil length 10700 Solar coil exchange surface 0.41 CH coil exchange surface...
  • Page 19: Product Sheet (In Compliance With Regulation 812/2013)

    3.7 PRODUCT SHEET (IN COMPLIANCE WITH REGULATION 812/2013). UB INOX SOLAR 200 ERP...
  • Page 20 Follow us Immergas Italia immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 Certified company ISO 9001 ИЗКЛЮЧИТЕЛЕН ПРЕДСТАВИТЕЛ И СЕРВИЗ АМАКС ГАЗ ООД 1261 Мрамор, София ул В. Левски 148 Tel. 0700 112 66 Fax 02 902 46 70...