Drive BP3200 Owner's Manual

Drive BP3200 Owner's Manual

Deluxe automatic blood pressure monitor

Advertisement

Owner's Manual
Deluxe Automatic Blood Pressure Monitor
Wrist Model
MODEL BP3200
Wrist Type
Safety Notice ................................................................ 02
Unit Illustration ............................................................... 06
Important Testing Guidelines ........................................ 09
Quick Start ..................................................................... 10
Unit Operation .............................................................. 12
Battery Installation ..................................................... 12
System Settings ........................................................ 13
Applying The Wrist Monitor ....................................... 16
Testing ....................................................................... 18
Power Off .................................................................. 23
Memory Check & Last 3 Tests Average .................... 25
Memory Deletion ....................................................... 27
Low Battery Indicator ................................................ 28
Troubleshooting ........................................................ 29
Blood Pressure Information .......................................... 30
Maintenance ................................................................. 36
Specifications ................................................................ 40
Warranty Specifications ................................................. 44
Safety Notice
Important Instructions Before Use
1.
Do not confuse self-monitoring with self-diagnosis. Blood pressure
measurements should only be interpreted by a health professional who
is familiar with your medical history.
2.
Contact your physician if test results regularly indicate abnormal
readings.
3.
If you are taking medication, consult with your physician to determine
the most appropriate time to measure your blood pressure. NEVER
change a prescribed medication without first consulting with your
physician.
4.
Individuals with serious circulation problems may experience
discomfort. Consult your physician prior to use.
5.
For persons with irregular or unstable circulation resulting from diabetes,
liver disease, arteriosclerosis or other medical conditions, there may be
variations in blood pressure values measured at the wrist versus at the
upper arm. Monitoring the trends in your blood pressure taken at either
the arm or the wrist is nevertheless useful and important.
6.
People suffering from vascular constriction, liver disorders or diabetes,
people with cardiac pacemakers or a weak pulse, and women who are
pregnant should consult their physician before measuring their blood
pressure themselves. Different values may be obtained due to their
condition.
Safety Notice
1
Thank you for purchasing the BP3200 Blood Pressure Monitor.
The unit has been constructed using reliable circuitry and durable
materials. Used properly, this unit will provide years of satisfactory use.
The device is intended for used by individuals 12 years and older to
measure the systolic and diastolic blood pressure and pulse rate. All
values can be read out in one LCD DISPLAY. Measurement position is on
adult upper arm only.
Blood pressure measurement determined with this device are equivalent
to those obtained by a trained observer using the cuff/ stethoscope
auscultation method, within the limits prescribed by the American National
Standard (ANSI/AAMI Sp10) for electronic sphygmomanometers.
Precautions to Ensure Safe, Reliable Operation
1. Do not drop the unit. Protect it from sudden jars or shocks.
2. Do not insert foreign objects into any openings.
3. Do not attempt to disassemble the unit.
4. Do not crush the pressure cuff.
5. If the unit has been stored at temperatures below 0 oC, leave it in a warm
place for about 15 minutes before using it. Otherwise, the cuff may not inflate
properly.
6. Do not store the unit in direct sunlight, high humidity or dust.
7. To avoid any possibility of accidental strangulation, keep this unit away from
children and do not drape tubing around your neck.
8. Ensure that children do not use the instrument unsupervised; some parts are
small enough to be swallowed.
9. Some may get a skin irritation from the cuff taking frequent readings over the
course of the day, but this irritation typically goes away on its own after
the monitor is removed.
3
Safety Notice
7. People suffering from arrhythmias such as atrial or ventricular
premature beats or atrial fibrillation only use this blood pressure
monitor in consultation with your doctor. In certain cases oscillometric
measurement method can produce incorrect readings.
8. Too frequent measurements can cause injury to the patient due to blood
flow interference.
9. The cuff should not be applied over a wound as this can cause further
injury.
10. Do not attach the cuff to a limb being used for IV infusions or any other
intravascular access, therapy or an arterio-venous (A-V) shunt. The cuff
inflation can temporarily block blood flow, potentially causing harm to the
patient.
11. The cuff should not be placed on the arm on the side of a mastectomy.
In the case of a double mastectomy use the side of the least dominant
arm.
12. Pressurization of the cuff can temporarily cause loss of function of
simultaneously used monitoring equipment on the same limb.
13. A compressed or kinked connection hose may cause continuous cuff
pressure resulting in blood flow interference and potentially harmful injury
to the patient.
14. Check that operation of the unit does not result in prolonged
impairment of the circulation of the patient.
15. Product is designed for its intended use only. Do not misuse in any way.
Document No.
Version: REV01.07.21.16
2
4

Advertisement

Table of Contents
loading

Summary of Contents for Drive BP3200

  • Page 1: Table Of Contents

    MODEL BP3200 Wrist Type Safety Notice Contents Thank you for purchasing the BP3200 Blood Pressure Monitor. Safety Notice ..............02 The unit has been constructed using reliable circuitry and durable Unit Illustration ............... 06 materials. Used properly, this unit will provide years of satisfactory use.
  • Page 2: Contents

    Safety Notice Unit Illustration Monitor Unit 16. Product is not intended for infants or individuals who cannot express their intentions. 17. Any hazards associated with prolonged overinflation of the bladder. World Health Organization (WHO) 18. Do not disassemble the unit or wrist cuff. Do not attempt to repair. Blood Pressure Classification Indicator 19.
  • Page 3: Quick Start

    Quick Start Unit Operation Battery Installation 4. Sit in a comfortable position and place wrist level with heart. Slide battery cover off as indicated by arrow. (See Figure D) Install 2 new AAA alkaline batteries according to polarity. 5. Press “ START/STOP ” button to start testing. (See Figure E) Close battery cover.
  • Page 4: Testing

    Unit Operation Unit Operation Do not stand while testing. Sit in a comfortable position and place wrist Testing level with heart. 1. Power On Press and hold “ START/STOP ” button until a beep sounds. The LCD screen will appear for one second as unit performs a quick diagnosis.
  • Page 5: Power Off

    Unit Operation Unit Operation Power Off 5. Deleting/Storing Test Results The “ START/STOP ” button can be pressed to turn off the unit User may delete their current test result due to unfavorable in any mode. testing conditions or for any other reason. To delete the last The unit can turn off the power itself about 3 minutes if there is no test result, press the “SET”...
  • Page 6: Troubleshooting

    Blood Pressure Information WHO Blood Pressure Classification Indicator Health Reminder The BP3200 is equipped with a classification indicator based on Hypertension is a dangerous disease that can affect the quality of established guidelines from the World Health Organization. life. It can lead to a lot of problems including heart failure, kidney The chart below (color coded on monitor unit) indicates test results.
  • Page 7: Blood Pressure Q&A

    Maintenance Specifications Do not disassemble product. Product Description Deluxe Automatic Blood Pressure Monitor, Wrist Model Model BP3200 Display LCD Digital Display Size: 49 mm × 38 mm Measurement Method Oscillometric Method Pressure 0mmHg ~ 300mmHg...
  • Page 8: Specifications

    This express warranty provided herein. In no event shall Drive Medical or product is free of hazardous materials. its subsidiaries by liable for loss of use or profit or other collateral,...