SolarEdge SE3000 Installation Manual page 83

Hide thumbs Also See for SE3000:
Table of Contents

Advertisement

Error #
Error #
Single
Three
Phase
Phase
Inverters
Inverters
144
145
SolarEdge Installation Guide – MAN-01-00057-2.0
LCD Message
Islanding –
AC grid voltage
Passive
malfunctions. The
inverter has shut off
due to islanding.
UDC Max
DC overvoltage. The
input DC voltage
exceeds the
maximum level that
is supported.
Errors and Troubleshooting
Description
When AC voltage returns the
inverter should restart after
some time (time depends on
country grid connection
codes)
If the problem persists, then
consult with the grid operator
whether frequent AC
disruptions have occurred at
the site.
The SolarEdge system should
normally eliminate DC
overvoltage errors. When DC
overvoltage is detected, the
inverter shuts off the power
optimizers and restarts the
inverter.
If the problem persists, then:
Turn OFF the ON/OFF
switch at the bottom of the
inverter. After at least five
minutes, the LCD panel
should show a low safety
voltage equal to 1 V *string
length. Otherwise, check
which string is
malfunctioning and recheck
its connections to the
inverter.
Verify that no PV modules
are connected directly to
the inverter without a
power optimizer.
Recommission all inverters
in the site, as described in
Chapter 4, Commissioning
the Installation on page 33.