LCD Message
Temperature
Over temperature.
Too High
Faulty Temp.
Broken or
Sensor
unconnected
Temperature sensor.
Isolation Fault The inverter
detected that the PV
solar generator is not
properly isolated
from ground earth.
Isolation is checked
every time the
inverter starts
operation.
Faulty AC
The AC relay failed
Relay
during wake-up
tests.
RCD Sensor
The RCD
Error
measurement
mechanism has
failed during the
wake-up test phase.
Errors and Troubleshooting
Description
If this fault persists, then:
Verify that there are proper
clearance distances around
the inverter, as described in
the Chassis Clearance
section on page 21.
Make sure that the heat-
sink fins are clear of dirt
and obstacles.
Check whether the inverter
is installed in an area that is
too hot.
Reinstall in a cooler
location.
If this fault persists, contact
SolarEdge support.
If this fault persists:
Check the PV installation
for isolation problems and
ground leakage.
Only a certified PV
installer must fix a faulty
string before connecting it
to the inverter.
If this fault persists:
Disconnect inverter from
AC grid.
Contact SolarEdge support.
If this fault persists, contact
SolarEdge support.