10, 37-38 76-77, 90 Ground
SolarEdge Installation Guide – MAN-01-00057-2.0
LCD Message
Ground current
Current - RCD
surge. The internal
hardware that
measures ground
fault has measured
substantially high
ground currents.
Errors and Troubleshooting
Description
Ground faults may occur due
to insufficient insulation to
the ground.
DO NOT TOUCH UN-
INSULATED WIRES!
EXTREME CARE MUST
BE TAKEN WHEN
TROUBLESHOOTING
THIS ERROR.
ELECTROCUTION RISK
EXISTS!
Only a qualified technician
should handle this problem,
and only after taking proper
precautions.
Shut OFF the inverter by
turning the ON/OFF switch
at the bottom of the inverter
OFF and disconnecting the
AC switch.
Wait five minutes for the
input capacitors to
discharge.
Disconnect the DC inputs.
For each DC string,
measure the DC voltage
between DC- and GND and
DC+ and GND with a
1Kohm resistor in parallel
to the volt meter. If a
voltage higher than 2 V is
measured, then the fault is
in this string.
Do not connect strings with
a grounding fault to the
inverter.
A certified PV installer
must fix the faulty string
before connecting it to the
inverter.