Ip Status Window; Fan Health Status Window - Three Phase Inverters - SolarEdge SE3000 Installation Manual

Hide thumbs Also See for SE3000:
Table of Contents

Advertisement

IP Status Window

After you press the inverter's LCD light button to display the window shown
above, you can press it again to display the Inverter IP Status window. This
window describes the Ethernet configuration.
I P
1 9 2 . 1 6 8 . 2 . 1 1 9
M S K
2 5 5 . 2 5 5 . 2 5 5 . 0
G W
1 9 2 . 1 6 8 . 2 . 1
M A C
0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
Fan Health Status Window – Three Phase Inverters
After you press the inverter's LCD light button to display the window shown
above, you can press it again to display the Fan Health Status window. This
window provides information about the health of the inverter's two fans, as
described below:
F a n
H e a l t h
F A N # 1 :
F A N # 2 :
Each fan can have one of the following statuses:
Operating
Replace
Not Working
When a fan has the status Replace, the display blinks constantly until it is
replaced, as long as the unit is not in night mode.
The Fault LED does not light when in Replace status.
The Error section displays an error if the fan is faulty. You may refer to
Appendix A, Errors and Troubleshooting on page 77 for a description of the error.
Clicking the LCD light button again redisplays the Initial Inverter Status window,
as described on page 63.
SolarEdge Installation Guide – MAN-01-00057-2.0
I n d i c a t o r
R e p l a c e
O p e r a t i n g
Inverter User Interface
66