Creating An Rs485 Bus Connection - SolarEdge SE3000 Installation Manual

Hide thumbs Also See for SE3000:
Table of Contents

Advertisement

Creating an RS485 Bus Connection

The RS485 option enables you to create a bus of connected inverters. Using this
option, inverters are connected to each other in a chain, meaning the first inverter
in the chain is connected to the next inverter in the chain via its RS485 connector.
The first inverter in the chain and the last inverter in the chain must be terminated.
Figure 27: Example of RS485 Bus Connection
Each inverter must be connected according to the instructions below.
To connect the RS485 communication bus:
1
Open the cover of the inverter, as described in the Opening the Cover section
on page 27.
2
Using the user buttons, select the RS485 option under the Communication
 Bus menu, as described in the Configuring the Inverter Using the LCD
Panel and User Buttons section on page 67.
3
For all slave devices, using the user buttons, select the RS485 option under
the Communication  Server menu, as described in the Configuring the
Inverter Using the LCD Panel and User Buttons section on page 67.
SolarEdge Installation Guide – MAN-01-00057-2.0
Setting Up Communication
54