Download Print this page
Elkay EZH20 LZWSM8* Installation, Care & Use Manual

Elkay EZH20 LZWSM8* Installation, Care & Use Manual

In wall bottle filling station
Hide thumbs Also See for EZH20 LZWSM8*:

Advertisement

Quick Links

Buy at
EZWSMD*1A
Installation/Care/Use Manual
LZWSM8*
EZWSM8*
Installer
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND
OTHER APPLICABLE CODES. After installation, leave these instructions inside the
fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLER BE PROTECTED BY A GROUND
FAULT CIRCUIT INTERRUPTER (GFCI)
1/4" O.D. TUBE
3/8" O.D. TUBE CONNECT
WATER INLET
TO COOLER
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
Fig. 1
| 855-558-9600 | BottleFillingStations.com
EZWSM8*1A
EZWSM8*2A
EZH20 In Wall Bottle Filling Station
LZWSMD*
EZWSMD*
IMPORTANT
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
Page 1
LZWSMD*1A
LZWSM8*1A
LZWSM8P*
LZWSMDP*
EZWSM8P*
EZWSMDP*
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE IS SECURED
TUBE IS SECURED
TUBE TO ATTACH
IN POSITION
TUBE TO ATTACH
IN POSITION
A
B
A
B
Fig. 2
LZWSM8*2A
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
C
C
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
98557C
(Rev. M - 06/16)

Advertisement

loading

Summary of Contents for Elkay EZH20 LZWSM8*

  • Page 1 Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station LZWSM8* LZWSMD* LZWSM8P* LZWSMDP* EZWSM8* EZWSMD* EZWSM8P* EZWSMDP* Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
  • Page 2 Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A LZWSM8*, LZWSMD* EZWSM8*, EZWSMD* ROUGH-IN Fig. 3 98557C (Rev. M - 06/16) Page 2...
  • Page 3 Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A LZWSM8P*, LZWSMDP* EZWSM8P*, EZWSMDP* ROUGH-IN Fig. 4 Page 3 98557C (Rev. M - 06/16)
  • Page 4: Installation Instructions

    Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A INSTALLATION INSTRUCTIONS Install mounting frame. See mounting frame instructions. Install remote chiller. See chiller instructions. EWF3000 WATERSENTRY PLUS FILTER INSTALLATION (Filtered units only. For non filtered units proceed to step 4b) NOTICE: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
  • Page 5: Mounting Frame

    Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A 10. Lock the door in place using two set screws (provided) on the side of the panel, and a ¼ x 20 bolt through the front of the panel into the nut in the frame.
  • Page 6 Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A BF6-BF7-BF8 PROGRAMS SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE RESETTING BOTTLE COUNT 1) To verify the software program of the control board the 1) Depress the program button for approximately 2 seconds unit will need to be shut down and restarted.
  • Page 7 Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A BF9 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE SETTING UNIT TYPE 1) To verify the software program of the control board the 1) Depress the program button for approximately 2 seconds unit will need to be shut down and restarted.
  • Page 8 Buy at | 855-558-9600 | BottleFillingStations.com EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again.
  • Page 9 PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.834.4816 IMPRIMÉ AUX É.-U. POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.834.4816 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 Page 9 98557C...