Id Status; Server Communication Status; Ip Status - SolarEdge storedge Installation Manual

Hide thumbs Also See for storedge:
Table of Contents

Advertisement

ID Status

 
Module: Power optimizer serial number
l
 
Energy: power optimizer energy
l
 
Vdc_O: Power optimizer output voltage
l
 
Vdc_I: Power optimizer input voltage (module voltage)
l
 
I_in: Power optimizer input current 
l
 
Temp: Power optimizer temperature
l
ID Status
This screen displays the inverter software version and the country to which the inverter is configured.
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 9 x x
C o u n t r y : U S A 1
 
ID: The inverter ID.
l
 
DSP 1/2: The DSP digital control board firmware version
l
 
CPU: The communication board firmware version
l
 
Country: the current country setting
l

Server Communication Status

S e r v e r : L A N
S t a t u s :
x x x x x x x x
< E R R O R
NOTE
If the connection method is CDMA (Cellular) or GSM, the server screen is replaced with the Cellular or
GSM status screens (see Cellular Status on the facing page and GSM Status on the facing page).
 
Server: The method of connection to the SolarEdge monitoring platform.
l
 
S_OK: The connection to the SolarEdge monitoring platform is successful (should appear only if the   i s 
l
connected to the server).
 
Status: Displays OK if the inverter established successful connection and communication with the 
l
specified server port/ (LAN, RS485 or ZigBee card).
 
xxxxxxxx: Eight-bit Ethernet communication connection status: A string of 1s and 0s is displayed. 1 
l
indicates OK, 0 indicates an error.   F or a list of the possible errors and how to troubleshoot them, refer 
to Communication   T roubleshooting on page 87.
 
Error message, according to failure. Refer to   T roubleshooting on page 87.
l

IP Status

This screen describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access 
Control) of the Inverter.
I P
1 9 2 . 1 6 8 . 2 . 1 1 9
M S K
2 5 5 . 2 5 5 . 2 5 5 . 0
G W
1 9 2 . 1 6 8 . 2 . 1
M A C
0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
64
< S _ O K >
< O K >
M E S S A G E >
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents