Drive BP3400 Owner's Manual

Drive BP3400 Owner's Manual

Deluxe automatic blood pressure monitor upper arm model

Advertisement

Owner's Manual
Deluxe Automatic Blood Pressure Monitor
Upper Arm Model
MODEL BP3400
Upper Arm Type
Contents
Safety Notice ............................................................................. 02
Unit Illustration ........................................................................... 05
Important Testing Guidelines .................................................... 08
Quick Start ................................................................................. 09
Unit Operation .......................................................................... 10
Battery Installation.................................................................. 10
System Settings ..................................................................... 11
Applying The Arm Cuff ........................................................... 13
Testing .................................................................................... 14
Power Off ............................................................................... 17
Memory Check ....................................................................... 18
Memory Deletion .................................................................... 19
Last 3 Tests Average .............................................................. 20
Low Battery Indicator ............................................................. 21
Troubleshooting ..................................................................... 22
Blood Pressure Information ...................................................... 23
Maintenance .............................................................................. 27
Specifications ............................................................................ 29
Warranty .................................................................................... 31
Drive Medical
99 Seaview Blvd
Port Washington, NY 11050
Toll-Free 877-224-0946
www.drivemedical.com
1
Safety Notice
Thank you for purchasing the BP3400 Blood Pressure Monitor. The unit has been constructed
using reliable circuitry and durable materials. Used properly, this unit will provide years of
satisfactory use.
The device is intended for use by individuals 12 years and older to measure the systolic and
diastolic blood pressure and pulse rate. All values can be read out in one LCD DISPLAY.
Measurement position is on adult upper arm only.
Blood pressure measurement determined with this device are equivalent to those
obtained by a trained observer using the cuff/ stethoscope auscultation method, within
the limits prescribed by the American National Standard (ANSI/AAMI Sp10) for electronic
sphygmomanometers.
Precautions to Ensure Safe, Reliable Operation
1.
Do not drop the unit. Protect it from sudden jars or shocks.
2.
Do not insert foreign objects into any openings.
3.
Do not attempt to disassemble the unit.
4.
Do not crush the pressure cuff.
5.
If the unit has been stored at temperatures below 0ºC, leave it in a warm place for about
15 minutes before using it. Otherwise, the cuff may not inflate properly.
6.
Do not store the unit in direct sunlight, high humidity or dust.
7.
To avoid any possibility of accidental strangulation, keep this unit away from children and
do not drape tubing around your neck.
8.
Ensure that children do not use the instrument unsupervised; some parts are small
enough to be swallowed.
9.
Some may get a skin irritation from the cuff taking frequent readings over the course of
the day, but this irritation typically goes away on its own after the monitor is removed.
Document No.
Version: REV01.07.21.16
2

Advertisement

Table of Contents
loading

Summary of Contents for Drive BP3400

  • Page 1: Table Of Contents

    Contents Safety Notice Safety Notice ................02 Thank you for purchasing the BP3400 Blood Pressure Monitor. The unit has been constructed using reliable circuitry and durable materials. Used properly, this unit will provide years of Unit Illustration ................05 satisfactory use.
  • Page 2: Safety Notice

    Safety Notice Safety Notice Important Instructions Before Use Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only 20. The system might produce incorrect readings if stored or used outside the manufacturer’s be interpreted by a health professional who is familiar with your medical history. specified temperature and humidity ranges.
  • Page 3: Important Testing Guidelines

    Unit Illustration Important Testing Guidelines Avoid eating, exercising, and bathing for 30 minutes prior to testing. Contents Sit in a calm environment for at least 5 minutes prior to testing. Do not stand while testing. Sit in a relaxed position while keeping your arm level with your heart.
  • Page 4: Unit Operation

    Unit Operation Unit Operation System Settings Saved Settings While in any setting mode, press “ START/STOP “ button to turn the unit off. With power off, press "SET" button to activate System Settings. The Memory Group icon All information will be saved. flashes.
  • Page 5: Power Off

    Unit Operation Unit Operation Pressurization Testing Initial pressure is first pumped to 190mmHg. If the current user’s systolic blood pressure After cuff inflation, air will slowly subside as indicated by the corresponding cuff is over 190mmHg, the unit will automatically re-inflate to the proper shelf. pressure value.
  • Page 6: Last 3 Tests Average

    Unit Operation Unit Operation Memory Deletion Last 3 Tests Average Memory for a selected group may be deleted while in Memory Check mode. Press and hold With power off, press the “ M ” button to activate screen display. After the unit the “...
  • Page 7: Blood Pressure Information

    Blood pressure is the force of blood pushing against the walls of arteries. It is typically The BP3400 is equipped with a classification indicator based on established guidelines measured in millimeters of mercury (mmHg.) Systolic blood pressure is the maximum from the World Health Organization.
  • Page 8: Maintenance

    Specifications Product Description Deluxe Automatic Blood Pressure Monitor, Upper Arm Model International Standards: Model BP3400 AAMI / ANSI SP10:2002/(R) 2008 & 2002/A1:2003/(R)2008 & 2002/A2:2006/(R)2008 Manual, electronic, or automated sphygmomanometers Display LCD Digital Display Size: 84.1mm × 55.1mm (3.31” x 2.17”)
  • Page 9: Warranty

    In no event shall Drive Medical or its subsidiaries by liable for loss of use or profit or other collateral, special or consequential damages.

Table of Contents