Swing Door Operator
Manual
1.
2.
Safety Instruction
3.
4.
5.
6.
Level adaptors for stand arms
7.
Installation instructions for standard arms
8.
Installation instructions for slide arms
9.
10. Adjusting possibilities for arms
11. Installation
14. Mech. control elements and indicators
16. Master/Slave applications
19. Control references for new assembly
21. Cable layout
22. Wiring diagram
Datum: 12/2006, BU Artikel-Nr.: 127.108.955 B
Automatic
DFA 127
E
Page
10 - 13
15 - 18
19 - 22
23 - 26
27 - 28
29 - 39
40 - 41
42 - 45
47 - 48
50 - 51
52 - 54
2
3
4
5
6
7
8
9
14
46
49

Advertisement

Table of Contents
loading

Summary of Contents for Record DFA 127

  • Page 1 Automatic Swing Door Operator DFA 127 Manual Page Description of the equipment Safety Instruction Technical Data Construction and Function Types of Arms Level adaptors for stand arms Installation instructions for standard arms Installation instructions for slide arms Assembly dimension diagrams 10 - 13 10.
  • Page 2 5 operational modes can be remotely selected with the external BDE-D, which is available as a flush-mounted or surface-mounted model. Master / Slave In the Master / Slave operation, two DFA 127 can be sequentially controlled without additional mechanical door locking systems. Not suitable for fire protection doors!
  • Page 3 Safety Instructions The DFA 127 has been constructed to the latest state-of-the-art and the recog- nised technical safety regulations, including, for example, limitation of forces and speeds. Danger can arise for users, however, if not used as intended. Installation, maintenance and repairs on the DFA 127 may only be car- ried out by qualified and authorised personnel.
  • Page 4 Key : J = mass moment of inertia [ Slide arms : J max. 65 kgm m = door leaf weight [kg] b = door leaf width [m] Page 4 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 5 16 Status signal and Reset button 4.2 Functions The record DFA 127 has been designed to close without electrical power. It can be easily opened by hand and closes using the energy stored in the spring, with the motion damped by the motor acting as a generator.
  • Page 6 Types of arms 5.1 Standard arm 5.2 Slide arm pulling 5.3 Slide arm pushing Page 6 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 7 * The measurements indicated refer to the lower edge of the operator. If the measurement is taken from the lower edge of the chassis, + 1.5 mm must be added Manual DFA 127 Full Power 12/2006 Rev. B Page 7 of 55...
  • Page 8 Installation plan for standard arms Lintel dimension X Article number Standard arm (in mm) SG 1 0…120 127.808.184 SG 2 100…220 127.808.215 SG 3 210…330 127.808.216 7.1 Chassis Page 8 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 9 Installation plan for slide arms 8.1 Slide arm pulling 8.2 Slide arm pushing Standard arm Lintel dimension X Article number (in mm) +/- 10 127.808.183 Manual DFA 127 Full Power 12/2006 Rev. B Page 9 of 55...
  • Page 10 Assembly dimension diagrams 9.1 Dimension diagram 1 for standard arms Page 10 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 11 Assembly dimension diagrams 9.2 Dimension diagram 2 for standard arms Manual DFA 127 Full Power 12/2006 Rev. B Page 11 of 55...
  • Page 12 Dimensional assembly diagrams 9.3 Dimensional diagram 1 for slide arm, pulling and pushing Page 12 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 13 Dimensional assembly diagrams 9.4 Dimensional diagram 2 for slide arm, pulling and pushing Manual DFA 127 Full Power 12/2006 Rev. B Page 13 of 55...
  • Page 14 CAUTION: All screwed connections must be firmly tightened! To lower the initial load, the lever arm can be adjusted at an angle of 6° in the counter rotation sense of the opening. Page 14 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 15 • Does the door leaf drop cleanly into the lock? • Have all damping devices been removed (not simply reset)? • Is the base on which the DFA 127 is to be mounted sufficiently stable? The chassis must lie as flat as possible. Coarse unevenness must be cleared or the bearing area must be made more powerful or be strengthened by means of additional plates.
  • Page 16 • Prepare the arms (refer to: 10 Adjustment of the arms), fix the arms in correct position with regard to the DFA, screw the arms to the door leafs and adjust the angle (90°) of the arms to the door leaf Page 16 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 17 If, for example, the arm moves away to the left when closing, the slide switch must be set to the left. Manual DFA 127 Full Power 12/2006 Rev. B Page 17 of 55...
  • Page 18 2. Check the external jumpers for auxiliary units that are not connected, such as EMERGENCY STOP, SIS, SIO 3. SIO / SIS (if present) must be connected and adjusted before the calibration run. Page 18 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 19 Carry out the spring teaching. Check the spring value and read- just if necessary. FPC 902: Slave / Parameter / Drive Check the correct settings for the / Arms type of arm Manual DFA 127 Full Power 12/2006 Rev. B Page 19 of 55...
  • Page 20 The door must not be obstructed in any way during the calibration run. In case of uncontrolled door motion, immediately disconnect the mains power supply by turning off the main switch or unplugging the mains power plug. Page 20 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 21 12.5 Configuration of specific customer settings The possibilities are described in chapter 15, “configurations” All modifications must be entered on the configuration sheet (located in the op- erator) Manual DFA 127 Full Power 12/2006 Rev. B Page 21 of 55...
  • Page 22 • Check all the DFA functions • Tighten the arm screw 12.10 Hand over to the client • Instruct the client • Hand over the operating manual • RESET demonstration Page 22 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 23 LD3: (green) +24V Lights up if +24V present. Caution: in the event of a power failure a processor reset takes place 1 second after this LED goes out. Manual DFA 127 Full Power 12/2006 Rev. B Page 23 of 55...
  • Page 24 In order to definitively carry out this function, a Reset must be initiated within 9 seconds (for example, with BDE-D, FPC 902, Test box). This can also take place on the DFA 127 via an EMERGENCY STOP. Page 24 of 55 12/2006 Rev.
  • Page 25 13.2 Functions of the BDE-D electronic controller (optional) The BDE-D electronic controller is an easily op- erated input and output device for the control and adjustment of record door operators. Logically arranged pushbuttons allow intuitive operation and navigation through the operator- specific menu.
  • Page 26 RESET After pushing the button for approx. 5 seconds, this status message on the display will read: Reset Operator? Push on the button again to reset the operator. Page 26 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 27 DFA will attempt to bring the door to the set open position for the next few seconds. If the obstacle is still present, the current position will be ac- cepted as the continuously-open position. Manual DFA 127 Full Power 12/2006 Rev. B Page 27 of 55...
  • Page 28 With the factory default setting, the mechanical BDI is always connected and ac- tive on a DFA 127. If an additional electronic BDE-D is connected, the operating mode will be set at the highest priority by a defined priority structure in the BDE.
  • Page 29 Configurations 15.1 Parameter Overview Factory settings: Basic operator (Full Power) Manual DFA 127 Full Power 12/2006 Rev. B Page 29 of 55...
  • Page 30 Configuration Configurations of the DFA 127 can only be made with the electronic BDE-D or the optional Testbox. If a toggle switch is connected, a BDE-D or Testbox must be con- nected briefly for the configuration. Please always leave the configuration review sheet in the drive even when the STG is replaced! 15.2 Parameter Description...
  • Page 31 Without Function not yet integrated interlock interlock Door type Basic Basic Frequently-used door types can be operator operator chosen for specific applications. USA Low Energy UK Low Energy Manual DFA 127 Full Power 12/2006 Rev. B Page 31 of 55...
  • Page 32 Opening or closing sequence on 40: The subsequent door leaf waits until the first leaf has entirely opened or closed. With this setting, the overlap has the highest priority. Page 32 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 33 0 - 40 Slide control with 40 steps, setting the closing speed as it sees fit. Pre- sent locks must lock in place. This depends on the adjusted spring force. Manual DFA 127 Full Power 12/2006 Rev. B Page 33 of 55...
  • Page 34 (AUTO) (AUTO) Function corresponds to the symbols (BDE-M) on the three-step rocker switch BDI on the side cover of the DFA 127. Automatic; Manual; Con. open; Locked 4-digit Adequate setting for time switch en- tries (e.g. SUR-V). Only possible with optional BDI-M.
  • Page 35 VAK. The opening is time-delayed. INPUT AUX1_IN Disabled Disabled Special function, currently for the USA only. Bodyguard AUX2_IN Special function, currently for the USA only. Railbeam Manual DFA 127 Full Power 12/2006 Rev. B Page 35 of 55...
  • Page 36 15.3 Different factory defaults for different door types EU Low Energy Parameter Factory Parameter Factory default default DRIVING CYCLE MANUAL CONTROL Closing speed During closing Enabled Opening speed Collision Enabled Acceleration Closing speed DRIVE Collision Page 36 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 37 If the value 2 has been programmed and an external mechanical BDE (BDE-M) has been connected, the inputs (BDE1, BDE2) will be interpreted in a different manner. On the circuit board in the mounting set, BDI-M DFA 127 (127.808.232) is equipped with clamps that permit the external adjustment of the operation mode according to the table below.
  • Page 38 List of parameters: If no BDE-D is connected and the DFA 127 is connected to an electronic lock, the “Always locked” operation mode must be configured. Menu: Locking / Locking function / Always locked For the correct function of “Manual operation with active sensors” the...
  • Page 39 BDE-M or external signals to the BDI-M circuit board after selec- tion of the "Locked" operating mode if it has been locked in the meantime with the BDE-D! Manual DFA 127 Full Power 12/2006 Rev. B Page 39 of 55...
  • Page 40 A particular feature of the master / slave control of the record DFA 127 is that all the safety functions recognised by the DFA also function with double-leaf doors.
  • Page 41 • Special function for overlap, opening and closing sequence Menu: MS 2-leaves / overlap, open sequence and closing sequence / Pa- rameter value 1 (Speedo) Manual DFA 127 Full Power 12/2006 Rev. B Page 41 of 55...
  • Page 42 Clear by service fitter Status 31: EMERGENCY STOP operated. Motor relay de-energises Reset by resetting the EMERGENCY STOP button Status 37: Motor current STG or ATE defective Reset by service fitter Page 42 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 43 Software update by service fitter Status 52: No running parameter Start calibration run Status 53: Interruption motor Possibly no connection to motor Reset by service fitter Status 54: Calibration run Reset automatically Manual DFA 127 Full Power 12/2006 Rev. B Page 43 of 55...
  • Page 44 Error in sense of rotation Status 96: EEPROM void Status 99: Operator rotates The grease in the gear will be dispersed. Automatic reset Status 105: Test brake Automatic reset Page 44 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 45 No motor detection during initialisation (motor temperature sensor). Check motor temperature sensor. Reset or reset by service fitter A status number with a "W" is a warning !! Manual DFA 127 Full Power 12/2006 Rev. B Page 45 of 55...
  • Page 46 Maintenance Instructions The following points must be checked: Is the DFA 127 securely fixed to the backing construction? Base fixing Is the attachment still normal? Chassis Can the door leaf be moved smoothly? Door hinge Has the fixing screw of the arm been firmly tightened?
  • Page 47 Control references with new assembly The following points must be checked: Is the DFA 127 securely fixed to the backing construction? Base fixing Is the attachment still normal? Chassis Door hinge Can the door leaf be moved smoothly? Do the leaf weight and the leaf width correspond to the defaults...
  • Page 48 Functional test of the electrical door lock and the monitoring (Input VAK; signal or switching contact). Casing Have the casing and the side cover plates been installed prop- erly? Logo Is the record logo correctly attached? Page 48 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 49 G GTR Gearing Instructions for wiring and assembly H HS Main switch 2-pole locking I IKG Encoder L LED Light Emitting Diode Light Emitting Diode Cable plan Manual DFA 127 Full Power 12/2006 Rev. B Page 49 of 55...
  • Page 50 Page 50 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 51 Manual DFA 127 Full Power 12/2006 Rev. B Page 51 of 55...
  • Page 52 Page 52 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 53 Manual DFA 127 Full Power 12/2006 Rev. B Page 53 of 55...
  • Page 54 Master / Slave installation: connect on both operators Page 54 of 55 12/2006 Rev. B Manual DFA 127 Full Power...
  • Page 55 Wishaw – North Lanarkshire – ML2 ORY CH-8320 Fehraltorf Phone + 44 1698 376411 Phone + 41 44 954 91 91 + 44 1698 376422 + 41 44 954 92 00 Manual DFA 127 Full Power 12/2006 Rev. B Page 55 of 55...