Summary of Contents for Immergas VICTRIX 20X TT 1E
Page 1
VICTRIX Instruction and warning book 20X TT 1E...
Page 3
Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will con rm your satisfaction for the Immergas product.
- Installation in places with a re risk is pro- relative Immergas accessories must have suitable hibited (for example: garages, closed parking features (technical and structural) such to allow...
2. e materials used for the central heating circuit of Immergas boilers withstand ethylene and propylene glycol based antifreeze liquids (if the mixtures are prepared perfectly). For life and possible disposal, follow the sup- plier's instructions.
IMMERGAS anti-back ow kit to be otherwise it is advisable to fit special filters used upstream of the cold water inlet connection upstream of the appliance to restore the purity of the boiler.
(CAR ) with climate chrono-thermostat When replacing the power supply cable, contact a function. In addition to the functions described quali ed company (e.g. the Immergas Authorised in the previous point, the CAR panel enables A er-Sales Technical Assistance Service).
Immergas chrono-thermostats. correlation between system ow temperature and external temperature is determined by the position of the central heating selector switch on...
Attention: the boiler must be installed ex- element in order to ensure sealing e ciency of clusively with an original Immergas “Green the coupling. Range” inspectionable air intake device and Attention: if the exhaust terminal and/or...
Page 11
Resistance Equivalent length Equivalent length Equivalent length Equivalent length TYPE OF DUCT Factor in m of concentric in metres of pipe in metres of pipe in m of concentric pipe Ø 60/100 Ø 80 Ø 60 pipe Ø 80/125 Intake m 7.3 Concentric pipe Ø...
(B53) or ustrade (W=0 if the balustrade is open). via an Immergas ducting system (B53). • Con guration without cover kit in a partially The technical regulations in force must be protected location (type C boiler) respected.
100. In this case the special extensions must subtracted. In this case the special extensions be requested. must be requested. Immergas also provides a Ø 60/100 simpli ed terminal, which in combination with its ex- tension kits allows you to reach a maximum extension of 11.9 metres.
1.14 CONCENTRIC VERTICAL KIT (3) concentric terminal pipe with the male end Ø 80/125 concentric terminal pipe with the male INSTALLATION. (5) (smooth) into the ange (2) up to the stop; side (smooth) to the female side of the adapter (1) Type C configuration, sealed chamber and making sure that the wall sealing plate has been (with lip gaskets) up to the end stop;...
1.15 SEPARATOR KIT INSTALLATION. will ensure sealing and joining of the elements Type C configuration, sealed chamber and making up the kit. fan assisted. • Installation clearances (Fig. 1-22). e mini- mum installation clearance measurements of Separator kit Ø 80/80. is kit allows air to come the Ø...
- Mount the cover (A) complete with adaptor (1) one must consider that 1 metre of ducted pipe is kit allows to install an Immergas boiler in and caps (6) on the wall and assemble the ue according to the indications described has a con guration "C93", achieving the combustion...
Ø 80 exible “Green Range” ducting systems must e appliance can be installed inside buildings method and requirements of the standards in only be used for domestic use and with Immergas or B mode; in this case, all technical rules force, by professionally quali ed technical sta .
- Clean the new system with a suitable cleaning means that the drain trap is lled with conden- activate the warranty of Immergas. e test certif- device (for example Sentinel X300, Fernox sate to the correct level preventing the passage icate and warranty is issued to the user.
Immergas supplies a kit made up from an ex- and open the by-pass, anticlockwise it is closed. tenance by cleaning the lter without having ternal cylinder unit and everything necessary to empty the circuit.
Never clean the appliance or connected parts of Immergas. We recommend stipulating a yearly with easily ammable substances. cleaning and maintenance contract with your Never leave containers or ammable substances zone Immergas Authorised A er-sales Service.
2.4 USING THE BOILER. With external probe present, the relative Attention: symbol (18) will appear on the display. In the the Victrix 20 X TT boiler was designed to oper- central heating phase, if the temperature of the ate as an appliance for room central heating only water contained in the system is su cient to or, coupled to a speci c optional kit, for central heat the radiators, the boiler can only function...
(1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical A er-Sales Service). e anomaly can only be veri ed in the list of errors in the “Information” menu...
Page 24
Press the Reset button (1) of so ware errors reached. (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical A er-Sales Service). e anomaly can only be veri ed in the list of errors in the “Information” menu...
A boiler anomaly has been detected Press the Reset button (1) (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical A er-Sales Service). e anomaly can only be veri ed in the list of errors in the “Information” menu 2.6 INFORMATION MENU.
BOILER COMMISSIONING a pressure of 1-1.2 bar. - ensure activation of all adjustment devices; INITIAL CHECK - switch the boiler on and check correct ignition; - check the production of DHW (when the boiler is connected to an external storage tank unit); - check the CO ow rate in the ue: To commission the boiler:...
Check that there Amico Remoto remote control (CAR ), which out by an authorised company (e.g. Immergas are no residues of material blocking the ow of must be connected to clamps 41 and 44 of the A er-Sales Technical Assistance Service).
DHW circuit by opening any out by an authorised company (e.g. Immergas the boiler is calibrated with the intermediate hot water tap. A er-Sales Technical Assistance Service).
3.8 ADJUSTING THE AIR GAS RATIO 3.9 FAST CALIBRATION. Once the function is active, the boiler sequential- During complete calibration (par. 3.7), you can is function allows you to calibrate the boiler ly carries out the procedures required to calibrate modify the values of the air - gas ratio.
3.10 FLUE TEST. Check the ΔP between the test pressures ( g. 1-30 3.11 PROGRAMMING THE P.C.B. To de ne the value to set in the ” ue length” Ref. 13), in compliance with the values indicated e boiler is prepared for possible programming “F0”...
Page 32
Default Parameter Description Range Parameter with “F0”= 0 750 ÷ 1700 1275 Min output e P.C.B. de nes the operating mode and the boiler output according to the combination of several parameters. e proper operating output of the appliance is de ned according to 5650 Max output the combination of the parameters of menus “n”...
Page 33
Parameter Description Range Default Parameter Central heating set point minimum De nes the minimum ow temperature. 20 ÷ 50 °C temperature Central heating set point maximum De nes the maximum ow temperature. (t0+5) ÷ 85 °C temperature On = -3°C Establishes the ignition and switch-o method of the boiler in DHW phase (when the boiler is O = +0°C connected to an external storage tank unit).
3.12 SOLAR PANELS COUPLING 3.18 AUTOMATIC VENT FUNCTION. - Verify the intervention of the ionisation ame FUNCTION. In the case of new central heating systems and control no gas device: e boiler is set-up to receive water. In the event in particular mode for oor systems, it is very - Check the CO by using the chimney sweep...
3.20 CASING REMOVAL. • Front (Fig. 3-15c). To facilitate boiler maintenance the casing can 6) Loosen the two screws (g). be completely removed as follows: 7) Pull the front (f) slightly towards you. • Lower grid (Fig. 3-15a). 8) Release front (f) from pins (h) pulling it 1) Loosen the two screws (a);...
Page 36
• Control panel (Fig. 3-15d). • Sides (Fig. 3-15e). 9) Press the hooks on the side of the control 11) Loosen screws (k) of side fastening (j). panel (i). 12) Remove the sides by extracting them from 10) Tilt the control panel (i) towards you. their rear seat (Rif.
3.21 VARIABLE HEAT OUTPUT. in length. Gas ow rates refer to net heating value N.B.: the power data in the table has been ob- below a temperature of 15°C and at a pressure tained with intake-exhaust pipe measuring 0.5 m of 1013 mbar.
3.24 KEY FOR DATA NAMEPLATE. Cod. Md Sr N° Cod. PIN Type n min. max. n min. n max. Class CONDENSING N.B.: the technical data is provided on the data plate on the boiler Model Cod. Md Model code Sr N° Serial Number Check Cod.
Page 40
Follow us Immergas Italia immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 Certi ed company ISO 9001...