Technical Specifications - Immergas SUPER CAR Instruction And Warning Book

Table of Contents

Advertisement

13.

TECHNICAL SPECIFICATIONS

• Supply: ......................................................................................... 24V nominal by means of a bifilar communication Bus
• Maximum voltage .......................................................................................................................................................32V
• Power input: ..........................................................................................................................................250 mW nominal
• Room working temperature: ............................................................................................................................. 0 - +40°C
• Warehouse temperature: ................................................................................................................................. -10 - +65°C
• Protection class in compliance with EN 60730: ..............................................................................................................II
• Protection class in compliance with EN 60529: ....................................................................................................... IP 20
• Container measurements (WxHxD): ........................................................................................................ 153 x 112 x 51
• Connection technique: .............................................................................................................................2 polarised wires
• Charge reserve time: ........................................................ 8 hours for hourly counting (with at least 2 hours for charging)
• Max. length of the connecting cable: ................................................................................. 50 m (with 2x0.75mm2 cable)
• Room temperature precision: ................................................................................................................+/- 0.5°C at 25°C*
• NTC room temperature sensor: ..................................................................................................................... 50 k a 25°C
• Clock deviation .................................................................................................................................. +/- 15 minutes/year
* = the indication of the room temperature can be influenced by where the Super CAR is installed (for instance on a warm
wall, cold wall, height from the floor, etc.).
28