11.3 Antifreeze level (NO FRS).

It lets you set room temperature at which the antifreeze
function starts. Adjustable from 0°C to 10°C; standard set-
ting is 5°C.

11.4 Telephone control (REMOTE).

It lets you set Super CAR operation so that if it is started
remotely it works with the automatic hourly programme if
the setting is AUT. or, vice versa, it works at a continuous
comfort temperature (with no hourly programme) if the
setting is ON.

11.5 Antilegionella function (LEGION).

It lets you start the Antilegionella function which takes storage
tank temperature to 65°C for 15 minutes. You can choose
whether to activate it once a day at 2 o'clock in the morning
(24h), every 7 days on Mondays at 2 o'clock in the morning
(7DY) or turn it off (OFF standard function).
Note: this function must only be turned on when there is a
storage tank and, if necessary, install a thermostat valve on the
outlet of the domestic hot water to avoid scalding.

11.6 Language selection (LANGUG).

It lets you select the Super CAR operating language. You have
a choice of Italian (ITA standard) and English (ENG).
12.

INFO

By pressing the
push button you access a menu that lets
you verify the Super CAR operating status.
Turn the selector to scroll the list and press it to select the vari-
ous items and options. The parameters that can be displayed
are listed below:
- T EXT: outside temperature (if the optional external tem-
perature probe is installed).
- CH TMP: central heating circuit delivery temperature.
- CH SET: value requested for the delivery temperature.
- CH RET: central heating circuit return temperature (only
with boilers where the return probe is installed).
- HW TMP: Storage tank water temperature or d.h.w. outlet
from the boiler.
- CH PRS: System pressure, central heating circuit.
- OTHER>: it visually displays the Super CAR software
version via the SERV option.
Note: the values displayed depend on the type of boiler to
which the Super CAR is connected.