Immergas VICTRIX 50 Instruction Booklet And Warning

Immergas VICTRIX 50 Instruction Booklet And Warning

Hide thumbs Also See for VICTRIX 50:
Table of Contents

Advertisement

VICTRIX 50
GB
Instruction booklet
and warning
Installer
User
Technician

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX 50

  • Page 1 VICTRIX 50 Instruction booklet and warning Installer User Technician...
  • Page 2 Dear Customer, Congratulations for choosing a high quality Immergas product designed to ensure lasting comfort and safety. As an Immergas customer you can always count on a professional Authorized Service Centre and qualified and updated personnel to gua- rantee the constant efficiency of your boiler.
  • Page 3: Table Of Contents

    VICTRIX 50 variable heat output.............................. 43 3.22 VICTRIX 50 technical data................................ 44 Immergas S.p.A. declines any responsibility for printing or transcription errors, and reserves the right to make any changes to its technical and commercial lists without prior notice.
  • Page 4: Boiler Installation

    1.1 Installation instructions. Immergas gas appliances must be installed exclusively by a professionally qualified and authorized technician. “VICTRIX 50” Range boilers can be installed outside or in a suitable room (heating station). Installation must meet the provisions of current standards and all applicable laws and regulations.
  • Page 5: Airing And Ventilation Of Installation Rooms

    5000 cm for LPG. Fume exhaust. e “VICTRIX 50” boiler must be connected to an efficient single flue. N.B.: With single installation, the “VICTRIX 50” can be connected to the Ø 80 mm flexible ducting system for condensing boilers (point 1.11 of this manual).
  • Page 6: External Installation

    1.4 External installation. e “VICTRIX 50” boiler has IPX5D protection rating and can also be installed outside, without requiring additional protection. Important: All the optional kits that can be connected to the boiler must be protected according to their electrical protection rating.
  • Page 7: Main Dimensions

    1.6 Main dimensions. Height (mm) Width (mm) Depth (mm) Key: V - Electrical connection G - Gas supply Connections R - System return M - System delivery SYSTEM SC - Condensate drain (min. internal diameter Ø 13 mm) 3/4” 1”1/2 1”1/2...
  • Page 8: Connections

    Electrical connection. e electrical system must be carried - Due to the composition of the LPG mixture, layering out in accordance with the law. e entire “VICTRIX 50” of the mixture components may occur during the period boiler has IPX5D protection rating. Electrical safety of the of storage in the tanks.
  • Page 9 When replacing the power supply cable, contact a - permanent operation in comfort temp.; qualified technician (e.g. the Immergas Technical Assistance - permanent operation in lower temp.; Service). e power cable must be laid as shown.
  • Page 10 • Zone manager. Zone and cascade regulator or On/Off chronothermostat In addition to the functions described in the previous (Optional) electrical connection. e following operations point, the zone manager panel enables the user to control must be carried out after disconnecting the electrical power sup- and have at hand all the important information regarding ply.
  • Page 11: Air Intake And Fume Exhaust Terminal Installation

    Important: the boiler must be installed exclusively with an original Immergas “Green Range” air intake and fume extraction system in plastic, as required by current regula- tions. is system is identifiable by a special distinctive marking giving the note: “for condensing boilers only”.
  • Page 12 Resistance factors and equivalent lengths tables. Equivalent Equivalent length in metres of length Resistance concentric pipe in metres of pipe TYPE OF DUCT Factor Ø 80/125 Ø 80 Concentric pipe Ø 80/125 m 1 Intake Exhaust 1.0 m exhaust 4.0 m 90°...
  • Page 13 Resistance factors and equivalent lengths tables. Equivalent length Equivalent length Resistance in m of concentric pipe in m of pipe TYPE OF DUCT Factor Ø 80/125 Ø 80 Pipe Ø 80 m 1 Exhaust Exhaust 0.24 m 1.0 m Complete exhaust terminal Ø 80 m 1 Exhaust Exhaust 0.63 m...
  • Page 14: Boiler Installation With "C" Type Configuration

    1.9 Boiler installation with “C” type configuration “VICTRIX 50” boilers leave the factory with “B ” type configuration (open chamber and forced draught), to change the configuration to “C” type (sealed chamber and forced draught), remove the Ø 80 adapter, the bracket and gasket present on the boiler cover.
  • Page 15 Vertical kit with aluminium tile Ø 80/125. is particular terminal enables fume exhaust and air intake Kit assembly: Fit the Ø 80/125 adapter (1) up to the stop necessary for combustion, in a vertical direction. on the central hole of the boiler. Slide the gasket (2) along e Ø...
  • Page 16: Installing "B23 " Type Single Boiler With Open Chamber And Forced Draught

    1.10 Installing “B ” type single boiler with open chamber and forced draught. “VICTRIX 50” boilers leave the factory in “B “ type con- figuration (open chamber and forced draught). Air is drawn directly from the place where the boiler is...
  • Page 17 Ø 80 horizontal kit with wall exhaust. Ø 80 horizontal kit with exhaust in flue. Kit assembly: Kit assembly: Fit the male end of the Ø 80 bend (1) up to Fit the male end of the Ø 80 bend (1) up to the stop on the stop on the central hole of the boiler.
  • Page 18: Existing Flue Ducting

    Immergas Ø 80 mm ducting system. e “Green Range” Ø 80 flexible ducting system must only be used with Immergas condensing boilers. In any case, ducting operations must respect the provisions contained in the standard and in current technical regulations;...
  • Page 19: Fume Exhaust With Boiler In Cascade

    Tighten the cap on completion. - the Ø 125 exhaust manifold must have a min. slope of 3%; N.B.: e “VICTRIX 50” boiler does not have an expansion tank on the system. A closed expansion tank must be installed - the drain for condensate produced by the appliances must to guarantee correct boiler operation.
  • Page 20: Filling Condensate Collection Trap

    - check gas supply tightness with the boiler gas ON/OFF 1.17 Circulating pump. cock closed, no gas flow must be indicated on the meter “VICTRIX 50” Range boilers are supplied with a built-in for 10 minutes; circulating pump with 3-position electric speed control. e boiler does not operate correctly with the circulating pump 1.16 Boiler start-up (lighting).
  • Page 21: Victrix 50 Boiler Components

    1.18 VICTRIX 50 boiler components. Key: 16 - Negative signal pressure point 1 - Electronic card 17 - System return adjustment NTC sensor 2 - Delivery manifold 18 - Overtemperature safety thermostat 3 - System pressure switch 19 - Fake electrode...
  • Page 22: Plumbing Diagram For Victrix 50 With Optionals

    (not supplied standard with the appliance) must be arranged S.p.A. declines any responsibility if the installer does not as described in the installation instructions. Whenever the use the original Immergas devices and kits or uses them generators are not installed in cascade according to the improperly.
  • Page 23: Plumbing Diagram With 2 Victrix 50 Appliances In Cascade With Optionals

    1.20 Plumbing diagram with 2 VICTRIX 50 appliances in cascade with optionals. N.B.: Modular generators installed in cascade with an original Immergas connection kit must be considered as a single appliance, taking the serial number (factory number) of the generator nearest the safety devices.
  • Page 24: Plumbing Diagram With 3 Victrix 50 Appliances In Cascade With Optionals

    1.21 Plumbing diagram with 3 VICTRIX 50 appliances in cascade with optionals. N.B.: Modular generators installed in cascade with an N.B.: e boiler must be shut down before closing one original Immergas connection kit must be considered or both system on/off cocks (9).
  • Page 25: Installation Examples - Victrix 50 Single Boiler

    1.22 Installation examples - VICTRIX 50 single boiler.
  • Page 26: Installation Examples - Victrix 50 Boilers In Cascade

    1.23 Installation examples - VICTRIX 50 boilers in cascade.
  • Page 27: Kits Available By Request

    1.24 Kits available by request. • Cascade and zone thermoregulator kit. • Support kit for thermoregulator wall fixing. • Zone manager kit. • Modulating room thermostat kit. • External sensor kit. • System delivery sensor kit. • Domestic circuit kit for external generator. •...
  • Page 28: User

    OPERATION AND MAINTENANCE INSTRUCTIONS 2.1 Cleaning and maintenance. Important: the user must have at least one servicing of the heating system and one combustion check (“flue test”) carried out every year. is ensures optimal boiler safety, performance and opera- tion over time. We recommend stipulating a yearly cleaning and mainte- nance contract with your area technician.
  • Page 29: Victrix 50 - Control Panel

    2.4 VICTRIX 50 - Control panel. Key: 1 - Main switch 2 - User interface display 3 - Boiler manometer Boiler lighting. Before lighting, make sure the system is full Burner lit (domestic hot water) of water and that the manometer (3) indicates a pressure...
  • Page 30 Parameters modifiable by the user. Para- Description Lower limit Upper limit Factory Value set by meter value value value User Domestic hot water setting value 20 °C 70 °C 20 °C Domestic hot water function mode 0 = cut out 1 = active 2 = cut out + continuous pump 3 = active + continuous pump...
  • Page 31: Restoring Heating System Pressure

    Boiler block with manual reset. Code Description Cure Flame presence inhibited Reset Ignition block Reset 03, 05, 06, Internal block (electronics) Reset, if this anomaly persists contact an 07, 11, 13, enabled technician 14, 15, 16, 17, 44, 60 Non-volatile block Reset Overtemperature safety thermostat intervention / 24 V fuse Reset, if this anomaly persists contact an...
  • Page 32: Antifreeze Protection

    2.7 Antifreeze protection. e boiler comes standard with an antifreeze function that starts the pump and burner when the system water tem- perature inside the boiler falls below 3°C. e antifreeze function is guaranteed if the boiler is fully operative and not in “block”...
  • Page 33: Boiler Start-Up (Preliminary Check)

    BOILER STARTUP PRELIMINARY CHECK To start up the boiler, proceed as follows: - ensure that the declaration of conformity of installation is supplied with the appliance; - check gas supply circuit tightness with the On/Off valves closed and subsequently open with gas valve closed; no gas flow must be indicated on the meter for 30 minutes;...
  • Page 34: Victrix 50 Wiring Diagram

    3.1 VICTRIX 50 wiring diagram. e connections of the M and O Bus terminals are used for room ermostat. managing boilers in cascade. Resistance R8 must be eliminated when connecting the e X40 jumper must be eliminated when connecting the...
  • Page 35: Victrix 50 Plumbing Diagram

    3.2 VICTRIX 50 plumbing diagram. Key: 1 - Exposed funnel discharge 18 - System delivery adjustment sensor 2 - 4 bar safety valve 19 - System return adjustment sensor 3 - Boiler drain cock 20 - Overtemperature safety thermostat 4 - Absolute pressure switch...
  • Page 36: Appliance Operational Parameters

    3.3 Appliance operational parameters. - press the MODE and STEP keys at the same time for 2 e following table gives the boiler adjustment parameters seconds; the display will show the wording CODE and with factory settings. subsequently a random number on the last two digits; To modify the parameters reserved for the technician, it is - change the value by operating the + or - keys until reaching necessary to enter an access code suppliable by request.
  • Page 37 Modulation hysteresis in domestic OFF -5 °C 30 °C Hysteresis detection in domestic ON -5 °C 30 °C Hysteresis detection in domestic OFF -20 °C 30 °C Heating timing 300 seconds Domestic timing 300 seconds Timing in transition from domestic to 0 = transition with burner on heating function 30 = transition with burner off...
  • Page 38: Operational Anomalies With Manual Reset

    3.4 Operational anomalies with manual reset. Code “E” Description Cure Flame presence inhibited Check detection electrode Check electronic card Ignition block Check gas valve Check electronic card 03, 05, 06, Internal block (electronic) Check electronic card 07, 11, 13, Replace electronic card 14, 15, 16, 17, 44, 60 Non-volatile block...
  • Page 39: Operating Anomalies With Electric Reset

    N.B.: maintenance must be performed by a qualified - Exchanger blocked. is may be caused by the trap being technician (e.g. Immergas Technical Assistance Service). blocked. Check, by means of the condensate drain cap, that there are no residuals of material blocking the flow - Smell of gas.
  • Page 40: Converting The Boiler To Another Type Of Gas

    N.B.: All boiler adjustment operations must be carried out by a qualified technician (e.g. Immergas Assistance Service). Burner adjustment must be carried out using a differential digital type pressure gauge (with scale in tenths of mm or...
  • Page 41: Combustion Parameters Check

    10 seconds in order to reduce the risk of the pump becoming blocked due to prolonged inactivity. 3.11 Rated heat output adjustment e “VICTRIX 50” boiler is produced with heat output 3.17 Radiator antifreeze function. set to maximum. erefore it is advisable not to change e boiler has a function that starts the pump when the...
  • Page 42 VICTRIX 50 electronic card DUNGS gas valve Key: 1 - Gas valve inlet pressure point 2 - Gas valve outlet pressure point 3 - Off/Set adjustment screw 12 - Outlet gas flow regulator F1 - 2A - 230 V fuse...
  • Page 43: Casing Removal

    3.19 Casing removal. - pull the bottom of the casing front (5) outwards while To facilitate boiler maintenance the casing can be completely pushing upwards at the same time (see figure); removed as follows: - undo the screws (2) on the top of the casing front support - remove the lower sheet protection grid;...
  • Page 44: Yearly Appliance Check And Maintenance

    - Check intervention of the device against no gas ionization - there must be no traces of blackening or burning. flame control; - ensure intervention time is less than ten seconds. 3.21 VICTRIX 50 variable heat output. METHANE (G20) BUTANE (G30) PROPANE (G31)
  • Page 45: Victrix 50 Technical Data

    3.22 VICTRIX 50 technical data. Rated heating power kW (kcal/h) 50.8 (43655) Min. heating power kW (kcal/h) 10.4 (8958) Rated heat output (useful) kW (kcal/h) 50.0 (43000) Min. heat output (useful) kW (kcal/h) 10.0 (8600) Useful thermal efficiency 80/60 Rated/Min.
  • Page 46 is instruction booklet is made of ecological paper ISO 9001 Certified Company Cod. 1.021347 Rev. 15.017686/000 - 02/04...