Immergas VICTRIX 50 User Manual

Immergas VICTRIX 50 User Manual

Wall mounted condensing boilers with low nox
Hide thumbs Also See for VICTRIX 50:

Advertisement

1
50 kW (43,000 kcal/h) wall-mounted premixed condensing boiler
with sealed or open chamber, forced draught, high efficiency and
forced circulation.
Approved for installation in both heating plants and outside buildin-
gs. Can be used in two configurations:
Open chamber and forced draught (appliance type B
- Does not need any additional kit as it leaves the factory in this
configuration.
Sealed chamber and forced draught (appliance type C
- if installed using the vertical or horizontal concentric kits.
The generator consists of:
• combustion system of the total premixing type with cylindricel
multigas burner made of steel, complete with ignition electrodes
and ionizing monitoring probe;
• pneumatic type gas valve with double shutter;
• primary gas/water exchanger with coil made of AISI 316L stainless
steel;
• combustion chamber in stainless steel insulated on the inside with
ceramic panels;
• fumes extraction fan with electronically variable speed;
• condensation disposal circuit including syphon and flexible drain
hose;
• hydraulics consisting of a delivery manifold, primary circuit
pressure switch, circulation pump including automatic air venting
valve;
• 4 bar system safety valve (ISPESL approved), pressure gauge for
the heating system;
• overtemperature safety thermostat;
• control panel equipped with electronic board with microprocessor
and infinite flame modulation for the heating process plus P.I.D.
monitoring, modulation ranging from 10.0 to 50.0 kW (from 8,600
to 43,000 kcal/h);
• system delivery regulating probe;
• system return regulating probe;
• heating delivery temperature with 20 to 85°C factory setting;
VICTRIX 50
Wall mounted condensing boilers with low NOx
VICTRIX 50 is the new wall-mounted condensing boiler for
room heating alone. It is pre-engineered for operation both
independently and in series (up to 3 appliances connected),
with the advantage of providing a globally higher efficien-
cy at lower running costs. Condensing technology allows
particularly high efficiency ratings to be achieved (4 stars,
as established by Directive 92/42/EEC). VICTRIX 50's high
power is ideal when it comes to heating domestic systems
that have to deal with large volumes (semi-detached houses,
small condominiums and apartment blocks) and for com-
mercial and industrial uses. If a single boiler is installed, an
external three-way valve can be connected so as to use it
with a separate water heater and produce domestic hot wa-
ter. A hydraulic manifold can also be connected to boost the
circulation in the system, thus making it versatile and quick
to install. When operation is in series, several distribution
manifolds can be connected by means of threaded mecha-
nisms. The special environment-friendly burner guarantees
particularly low polluting emissions (the boiler belongs to the
most environment-friendly class established by the European
standards, i.e. class 5).

SPECIFICATIONS

• ignition delayer during the heating phase, antifreeze protection,
pump anti-blocking system, chinmey-sweep function;
• the boiler operating parameters can be entered and regulated by
means of keys while the status and operating modes are shown
on the 4-digit display;
/ B
)
• autodiagnosis system with digital display of the temperature,
23
33
the operating status and error codes on the permanently visible
display;
/C
/C
)
• IPX5D electrical insulation degree;
13
33
63
• pre-engineered for connection of the Series Regulator and external
probe;
• pre-engineered for connection of an external three-way valve for
use with a separate water heater in order to produce domestic hot
water;
• pre-engineered for operation in series (up to 3 generators);
• pre-engineered for installation of the ISPESL-approved safety
stub pipe;
• can be used with the Ø 80 mm hose pipe connecting system.
Supplied complete with traps for combustion analysis, bottom
protection grille and gas on-off cock.
Natural gas and L.P.G. fuelled Class II
The following model is available:
• VICTRIX 50
NOTE: to correctly install the boiler, use the "Green series" Immergas
air intake/fumes exhaust kit dedicated to the VICTRIX 50 boiler in
both the single and series (bank) configurations.
1
appliance. CE marking.
2H3+
code 3.015276

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX 50

  • Page 1: Specifications

    NOTE: to correctly install the boiler, use the "Green series" Immergas • control panel equipped with electronic board with microprocessor air intake/fumes exhaust kit dedicated to the VICTRIX 50 boiler in and infinite flame modulation for the heating process plus P.I.D.
  • Page 2 VICTRIX 50 MAIN COMPONENTS LEGEND: 15 - Positive signal pressure point - Electronic board 16 - Negative signal pressure point - Delivery manifold 17 - System return regulating NTC probe - System pressure switch 18 - Overtemperature safety thermostat - Condensation drain pipe...
  • Page 3 VICTRIX 50 MAIN DIMENSIONS Model Height mm Width mm Depth mm VICTRIX 50 CONNECTIONS Upper casing line SC = Condensation discharge Distance between upper casing line and Ø 80 outlet Distance between upper casing line and Ø 80/125 elbow: 170 mm...
  • Page 4 For ISPESL planning reasons, an ISPESL-approved pressure tdoors, these safety devices and components must therefore gauge must be added when the Immergas safety kit is instal- be adequately protected. led (as part of the standard supply, the boiler comes already...
  • Page 5 The system return is pre-engineered with an expansion tank Immergas declines all liability if the installer fails to use the connection. genuine ISPESL-approved devices and kits manufactured by The modular generators, or ones installed in the series Immergas, or uses them improperly.
  • Page 6 VICTRIX 50 CIRCULATOR HEAD AND FLOW RATE GRAPH VICTRIX 50 boilers are supplied with built-in circulator and mes already equipped with condenser. In new systems (single three-position electric speed governor. pipe and modules), it is advisable to use the circulator pump The circulator is the single-phase type (230 V - 50 Hz) are co- at top speed to obtain optimum operation from the boiler.
  • Page 7 This is why the VICTRIX 50 generator can be fitted with a • Individually (with the system divided into zones) using the series of accessories able to optimize the climatic adjustments series regulator with either the zone controller or modulating made to the entire system.
  • Page 8 VICTRIX 50 ZONE CONTROLLER (CE 3.015264) The zone controller only operates in conjunction with the series regulator. Besides the functions described for the series thermoregulator, it allows the user to keep all the important information concerning the operation of the appliance and heating system under control and particularly ready to hand.
  • Page 9 VICTRIX 50 MODULATING AMBIENT THERMOSTAT (CODE 3.015245) The modulating ambient thermostat (not a conventional On/Off model) only operates in conjunction with the series regulator and allows the user to regulate the ambient tempe- rature of one of the zones into which the system is divided (both in individual and series installations).
  • Page 10 VICTRIX 50 EXAMPLES OF VICTRIX 50 INSTALLATIONS WITH A SINGLE BOILER...
  • Page 11 VICTRIX 50 EXAMPLES OF VICTRIX 50 INSTALLATIONS IN SERIES...
  • Page 12 VICTRIX 50 WIRING DIAGRAM OPTIONAL ELECTRICAL CONNECTIONS. The domestic water probe (B2) must be connected to termi- The M and O terminals of thr Bus are connected in order to nals R and H, eliminating the resistance (R8). use the series and zone regulator.
  • Page 13 VICTRIX 50 HYDRAULIC LAYOUT LEGEND: - Visible funnel outlet 15 - Air analyzer intake - ISPESL-approved 4 bar safety valve 16 - Fumes analyzer intake - Boiler emptying cock 17 - Δp gas pressure point - Absolute pressure switch 18 - System delivery regulating probe...
  • Page 14 The "VICTRIX 50" boiler leaves the factory in the "B " confi- The boiler is installed using the Ø 80 adapter provided with the guration (open chamber and forced draught). To change the boiler as part of the standard supply and to which the relative boiler configuration to type "C"...
  • Page 15 VICTRIX 50 Ø 80/125 CONCENTRIC HORIZONTAL KIT (CODE 3.015242) THE KIT INCLUDES: 1 - 1 (one) Ø 80/125 adapter 2 - 1 (one) seal Part (3) is standard supply with the boiler 4 - 1 (one) Ø 80/125 concentric elbow a 87°...
  • Page 16 VICTRIX 50 Ø 80/125 CONCENTRIC VERTICAL KIT (CODE 3.015243) THE KIT INCLUDES: MAXIMUM TOLERATED LENGTH OF 1 - 1 (one) Ø 80/125 adapter Ø 80/125 VERTICAL KIT 2 - 1 (one) seal Available resistance factor Part (3) is standard supply with the boiler...
  • Page 17 VICTRIX 50 Ø 80 VERTICAL KIT (CODE 3.015256) THE KIT INCLUDES: MAXIMUM TOLERATED LENGTH OF 1 - 1 (one) rose Ø 80 VERTICAL KIT 2 - 1 (one) Ø 80 exhaust terminal Available resistance factor Vertical meters...
  • Page 18 VICTRIX 50 Ø 80 HORIZONTAL TERMINAL KIT FOR 20.1 Ø 80 HORIZONTAL TERMINAL KIT FOR WALL-MOUNTED EXHAUST (CODE 3.015255) STACK EXHAUSTS (CODE 3.015254) THE KIT INCLUDES: THE KIT INCLUDES: 1 - 1 (one) 90° Ø 80 elbow 1 - 1 (one) 90° Ø 80 elbow 2 - 1 (one) Ø...
  • Page 19 VICTRIX 50 RESISTANCE FACTORS AND EQUIVALENT LENGTHS Each component of the air intake/combustion product The resistance factors and equivalent losses in meters are exhausting system possesses a resistance factor calcu- given in the catalogue in relation to: lated by means of tests and given in the following tables.
  • Page 20 VICTRIX 50 Equivalent Equivalent Resistance length in m of Ø 80/125 length TYPE OF DUCT Factor concentric pipe in m of Ø 80 pipe Ø 80/125 m 1 concentric pipe Intake 4.0 m 1.0 m exhaust exhaust 90° elbow Ø 80/125 concentric pipe Intake 7.9 m...
  • Page 21 VICTRIX 50 Equivalent Equivalent Resistance length in m of Ø 80/125 length in m of TYPE OF DUCT factor concentric pipe Ø 80 pipe Ø 80 m 1 pipe 1.0 m 0.24 m exhaust exhaust Terminal complete with Ø 80 m 1 exhaust pipe 2.6 m...
  • Page 22 VICTRIX 50 FUMES EXHAUSTING MANIFOLD KIT WITH TWO BOILERS IN SERIES (CODE 3.015240) THE KIT INCLUDES: 1 - 1 (one) stub pipe with air lock 2 - 1 (one) stub pipe with air lock 4 - 1 (one) elbow (can be inspected)
  • Page 23 VICTRIX 50 Ø 80 HOSE PIPE DUCTING SYSTEM The Immergas Ø 80 mm hose pipe ducting system for already existing stacks comprises a series of components, considered as single kits, which can be assembled to suit the specific installation requirements. This system is supplied in a con- figuration that includes an 87°...
  • Page 24 VICTRIX 50 TECHNICAL SPECIFICATIONS VICTRIX 50 Maximum nominal heat input kW (kcal/h) 50.8 (43,655) Maximum nominal heat output kW (kcal/h) 50.0 (43,000) Minimum nominal heat input kW (kcal/h) 10.4 (8,958) Minimum nominal heat output kW (kcal/h) 10.0 (8,600) 100% Pn efficiency (80/60°C) 98.5...
  • Page 25 VICTRIX 50 COMBUSTION SPECIFICATIONS OF VICTRIX 50 Nat.gas (G20) LPG (G30) GPL (G31) 100% Pn combustion efficiency (80/60°C) 98.75 98.75 98.75 P min combustion efficiency (80/60°C) 97.5 97.5 97.5 100% Pn useful efficiency (80/60°C) 98.5 98.5 98.5 P min useful efficiency (80/60°C) 96.0...
  • Page 26 VICTRIX 50 OPTIONALS Series and zone thermoregulator kit Support kit for fixing thermoregulator to the wall code 3.015244 code 3.015265 Zone controller kit External probe kit code 3.015264 code 3.015266 Modulating ambient thermostat kit System delivery probe kit code 3.015245 code 3.015267...
  • Page 27 VICTRIX 50 ISPESL safety pipe kit for single boiler ISPESL safety pipe kit for boilers in series code 3.015222 code 3.015227 Hydraulic manifold kit for connection Hydraulic manifold kit for additional boiler in series of two boilers in series code 3.015226 code 3.015225...
  • Page 28 VICTRIX 50 Three-way valve kit for use with external UB 200 double water heater connection kit water heater unit code 3.015273 (including water heater probe) code 3.015223 UB 200 re-circulation kit UB 200 connection kit for re-circulation in parallel code 3.015274 code 3.015342...
  • Page 32 The data indicated in this brochure refer to new products, installed and used in compliance with the cur- rent standards in force. NOTE: remember have your appliance periodically serviced. 42041 Brescello (RE) Italy - Tel. 0522.689011 - Fax 0522.689102 www.immergas.com...