3.3.11
OVERVOLTAGE
If the bus voltage rises above 15.3 volts, a bright red
"High Volts" light will illuminate.
Battery Master Switch.............................................. Off
Wait 1 minute and switch master switch on and monitor
voltage. If the "High Volts' light comes on again, pull
alternator and field circuit breakers and continue flight as
failed alternator, determine what electrical equipment is
essential to continue the flight and land as soon as
practical. Battery power is the only source of electrical
power. Anticipate complete electrical failure.
3.3.12
INADVERTENT SPIN
Aileron Control ................................................. Neutral
Throttle ............................................................ Closed
Rudder ................................................... Full opposite
(Opposite to direction of spin)
Elevator ............................................. Control Forward
(To break stall)
Elevator and Throttle ................................ As required
(To resume level flight smoothly)
If flaps were down, retract once a safe flying speed
has been attained. Ensure that the flap speed is not
exceeded (89 mph or 77 knots IAS).
This recovery procedure is applicable only when the
aircraft is in a spin. Application of controls as
described above during a stall or after the aircraft
has stopped gyrating may cause the aircraft to enter
Issued: 05/31/05
Date of Revision: 11/20/12
EMERGENCY PROCEDURES
CAUTION
into a spin.
SECTION 3