Cub Crafters CC18-180 Pilot Operating Handbook page 220

Hide thumbs Also See for CC18-180:
Table of Contents

Advertisement

SECTION 9.4
SUPPLEMENTS-EDM-800
Temperature Units (°F or °C)
● °F temperatures in the digital display are in Fahrenheit
degrees.
● °C temperatures in the digital display are in Celsius
degrees.
Cylinder Numbers and Dot Index
A row of numbers 1 through 6 and the letter T are the
column labels for the bar display. The 1 through 4 are
the cylinder numbers (numbers 5 and 6 are disabled as
the engine has four cylinders). A round dot under the
numbers 1 through 4 indicates that particular column is
shown numerically in the EGT and CHT digital display
 Bar Graph EGT and CHT
Each column in the bar graph is composed of a stack of
segments. The total height of each column represents
the EGT and the missing segment in the column
represents the CHT.
● In the Percentage view, the EGT resolution depends
on the programmed maximum limits.
● CHT is displayed by a missing segment and should be
interpreted as follows: a missing segment corresponds to
the CHT in 25 F° increments, starting at 300°F at the
bottom. In the example shown in Figure 9-4-3, the CHT is
350°F. If the EGT bar is lower than the missing CHT
segment, then the CHT will be indicated by a single
isolated lighted segment.
The CHT display is the not affected by mode or view.
REPORT TC10000AFM
Page number 9-4-8
CUB CRAFTERS
CC18-180
Issued: 5/31/05
Date of revision: 12/06/05