Sign In
Upload
Manuals
Brands
DAIKIN Manuals
Air Conditioner
Super Multi NX FDXS25EAVMB
DAIKIN Super Multi NX FDXS25EAVMB Manuals
Manuals and User Guides for DAIKIN Super Multi NX FDXS25EAVMB. We have
8
DAIKIN Super Multi NX FDXS25EAVMB manuals available for free PDF download: Service Manual, Operation Manual, Installation Manual
Daikin Super Multi NX FDXS25EAVMB Service Manual (501 pages)
E-Series, F-Series, G-Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 28.58 MB
Table of Contents
Table of Contents
4
Introduction
8
Safety Cautions
8
Used Icons
12
Part 1 List of Functions
13
Functions
14
Cooling Only - Indoor Unit
14
Cooling Only - Outdoor Unit
20
Heat Pump - Indoor Unit
21
Heat Pump - Outdoor Unit
28
Part 2 Specifications
29
Cooling Only - Indoor Unit
30
Cooling Only - Outdoor Unit
41
Heat Pump - Indoor Unit
43
Heat Pump - Outdoor Unit
57
Part 3 Printed Circuit Board Connector Wiring Diagram
61
Indoor Unit
62
Wall Mounted Type
62
Floor Standing Type
71
Floor / Ceiling Suspended Dual Type
73
Duct Connected Type
75
Ceiling Mounted Cassette Type
77
Ceiling Mounted Built-In Type
81
Ceiling Suspended Type
86
Remote Controller
88
Wired Remote Controller
88
Wireless Remote Controller
90
Outdoor Unit
92
Part 4 Function and Control
95
Function of Indoor Unit (RA Models)
96
Temperature Control
96
Frequency Principle
96
Operation Starting Control
98
Airflow Direction Control
99
Fan Speed Control for Indoor Units
101
Program Dry Operation
102
Automatic Operation
103
Thermostat Control
104
NIGHT SET Mode
106
ECONO Operation
107
HOME LEAVE Operation
108
2-Area INTELLIGENT EYE Operation
109
INTELLIGENT EYE Operation
111
Inverter POWERFUL Operation
112
Other Functions
114
Function of Indoor Unit (SA Models)
116
Drain Pump Control
116
Thermostat Sensor in Remote Controller
118
Freeze Prevention Control
120
Hot Start Control (in Heating Operation Only)
121
Function of Thermistor
122
Control Specification
124
Mode Hierarchy
124
Frequency Control
125
Controls at Mode Changing / Start-Up
128
Discharge Pipe Temperature Control
129
Input Current Control
130
Freeze-Up Protection Control
130
Heating Peak-Cut Control
131
Outdoor Fan Control
131
Liquid Compression Protection Function
132
Defrost Control
132
Low Hz High Pressure Limit
133
Electronic Expansion Valve Control
133
Pressure Equalizing Control
135
Malfunctions
138
Part 5 Operation Manual
140
System Configuration
141
RA Indoor Unit
142
FTXG, CTXG Series - ARC466A1
142
Name of Parts
144
Fan Operation
146
Operating Conditions
147
FTXS, FVXS Series - ARC452A1, A3
166
Names of Parts
172
Opening the Front Panel
173
ATXS, FLK(X)S, FDK(X)S Series - ARC433B67, B68, B69, B76
202
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
224
Brc1D528
224
Brc1E51A7
239
Operation Mode
242
Automatic Operation Mode
242
Program Dry
249
Key Lock
253
Airflow Direction
260
Ventilation Mode
264
Timer Settings
264
Schedule Timer
266
Holiday Setting
270
Convenient Functions
275
Contrast Adjustment
275
Clock Setting
278
Setting the Clock
278
Useful Information
283
Brc7E530W/531W, Brc7F532F/533F, Brc7Ea63W/66
284
Operation Range
287
Operation Procedure
288
Part 6 Service Diagnosis
296
Troubleshooting with LED
298
Indoor Unit
298
Outdoor Unit
300
Problem Symptoms and Measures
301
Service Check Function
302
RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
302
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
311
Code Indication on Remote Controller
318
RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S
318
FDK(X)S Series
318
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
318
RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
318
Outdoor Unit
319
Troubleshooting for RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
320
Indoor Unit PCB Abnormality
320
Freeze-Up Protection Control or Heating Peak-Cut Control
321
Fan Motor or Related Abnormality
323
Thermistor or Related Abnormality (Indoor Unit)
326
Front Panel Open / Close Fault (FTXG and CTXG Series)
327
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
328
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
330
Troubleshooting for SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
331
Indoor Unit PCB Abnormality
331
Drain Water Level System Abnormality
332
Fan Motor or Related Abnormality
334
Swing Motor Lock (FHQ Series)
336
Drain System Abnormality
337
Thermistor or Related Abnormality
338
Remote Controller Thermistor Abnormality
340
Signal Transmission Error
341
(Between Indoor Unit and Remote Controller)
341
Signal Transmission Error (between Indoor Unit and Remote Controller)
341
Signal Transmission Error
342
(Between MAIN Remote Controller and SUB Remote Controller)
342
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
342
Field Setting Abnormality
343
Troubleshooting for Outdoor Unit
345
Anti-Icing Function
345
Outdoor Unit PCB Abnormality
347
OL Activation (Compressor Overload)
348
Compressor Lock
349
DC Fan Lock
350
Input Overcurrent Detection
351
Discharge Pipe Temperature Control
352
High Pressure Control in Cooling
353
Compressor Sensor System Abnormality
355
Position Sensor Abnormality
357
CT or Related Abnormality
359
Thermistor or Related Abnormality (Outdoor Unit)
361
Electrical Box Temperature Rise
363
Radiation Fin Temperature Rise
365
Output Overcurrent Detection
367
Refrigerant Shortage
369
Low-Voltage Detection or Over-Voltage Detection
371
Signal Transmission Error (on Outdoor Unit PCB)
372
Anti-Icing Function in Other Rooms / Unspecified Voltage (between Indoor and Outdoor Units)
373
Check
374
Thermistor Resistance Check
374
Fan Motor Connector Check
375
Hall IC Check
375
Power Supply Waveform Check
375
Electronic Expansion Valve Check
376
Four Way Valve Performance Check
377
Inverter Unit Refrigerant System Check
377
Inverter Checker" Check
378
Rotation Pulse Check on the Outdoor Unit PCB
379
Installation Condition Check
380
Discharge Pressure Check
380
Outdoor Fan System Check
381
Capacitor Voltage Check
381
Power Module Check
381
Advertisement
Daikin Super Multi NX FDXS25EAVMB Service Manual (398 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 14.81 MB
Table of Contents
Table of Contents
3
Introduction
8
Safety Cautions
8
Caution in Repair
8
Cautions Regarding Products after Repair
9
Inspection after Repair
10
Using Icons
11
Using Icons List
11
Part 1 List of Functions
12
List of Functions
13
Part 2 Specifications
20
Specifications
21
Outdoor Units
21
BP Unit
22
Indoor Units
23
Ceiling Mounted Cassette Type
31
Part 3 Printed Circuit Board Connector Wiring Diagram
34
Printed Circuit Board Connector Wiring Diagram
35
Outdoor Unit RMXS 112/140/160 E7V3B
35
Branch Provider Unit
40
Wall Mounted Type 20/25/35/50 Class - D Series
41
Wall Mounted Type 20/25/35 Class - C Series
44
Wall Mounted Type 50/60/71 Class - E(B) Series
46
Duct Connected Type
48
Floor / Ceiling Suspended Dual Type
50
Floor Standing Type
53
Ceiling Mounted Cassette 600×600 Type
56
Ceiling Suspended Type
58
Part 4 Refrigerant Circuit
60
Refrigerant Circuit
61
Outdoor Units
61
Refrigerant Circuit Part
61
BP Units
63
Functional Parts Layout
64
Outdoor Units
64
Refrigerant Flow for each Operation Mode
65
Cooling Operation
65
Heating Operation
66
Cooling Oil Return Operation
67
Heating Oil Return Operation & Defrost Operation
68
Part 5 Function
70
Operation Mode
71
Basic Control
72
Normal Operation
72
Compressor PI Control
73
Electronic Expansion Valve PI Control
76
Cooling Operation Fan Control
77
Special Control
78
Startup Control
78
Oil Return Operation
79
Defrosting Operation
81
Pump-Down Residual Operation
82
Restart Standby
82
Stopping Operation
83
Protection Control
84
High Pressure Protection Control
84
Low Pressure Protection Control
85
Discharge Pipe Protection Control
86
Inverter Protection Control
87
Freeze-Up Protection Control
88
Dew Condensation Prevention Control
89
Other Control
90
Demand Operation
90
Heating Operation Prohibition
90
BP Unit Control
91
BP Unit Command Conversion
91
BP Unit Electronic Expansion Valve Control
92
Full Closing of Electronic Expansion Valves
93
SH Control in Cooling Operation
94
SC Control in Heating Operation
95
Heat Exchanger Isothermal Control in Heating Operation
95
Indoor Unit (RA Models)
96
Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing
96
Fan Speed Control for Indoor Units
97
Programme Dry Function
98
Automatic Operation
99
Thermostat Control
100
Night Set Mode
101
ECONO Mode
102
Intelligent Eye
103
HOME LEAVE Operation
105
Inverter POWERFUL Operation
106
Other Functions
107
Indoor Unit (Skyair Models)
109
Function Outline
109
Electric Function Parts
110
Function Details
111
Part 6 Test Operation
122
Test Operation
123
Procedure and Outline
123
Check Operation
126
Outdoor Unit PCB Layout
128
Field Setting
129
Field Setting from Outdoor Unit
129
Detail of Setting Mode
138
Field Setting for Skyair Indoor Unit
147
Explanation
147
Field Setting
148
Initial Setting Contents
149
Local Setting Mode Number
150
Detailed Explanation of Setting Modes
151
Centralized Group No. Setting
155
Maintenance Mode Setting
156
Test Operation and Field Setting for RA Indoor Unit
157
Test Operation from the Remote Control
157
Jumper Settings
158
Part 7 System Configuration
160
System Configuration
161
Operation Instructions
161
Instruction
162
RMXS Series
162
Wall Mounted, Duct, Floor/Ceiling, Floor Standing Type
163
Safety Precautions
164
Installation Site
165
Electrical Work
165
Names of Parts
166
Indoor Unit
169
Outdoor Unit
170
Remote Control
171
To Set the Clock
186
To Change the Air Flow Rate Setting
188
Adjusting the Air Flow Direction
189
Air Flow Selection
198
Powerful Operation
199
Outdoor Unit Silent Operation
200
Econo Operation
201
Intelligent Eye Operation
204
Timer Operation
210
To Use on Timer Operation
211
To Combine on Timer and off Timer
211
Note for Multi System
212
Priority Room Setting
213
Care and Cleaning
214
Air Filter
215
Before a Long Idle Period
216
Front Panel
217
Cleaning the Air Filter
223
Front Grille
230
Troubleshooting
233
These Cases Are Not Troubles
233
Ceiling Mounted Cassette Type
238
Temperature Setting
243
Fan Speed Control
243
Ceiling Suspended Type
249
Operation Range
252
Air Flow Direction Adjust
254
Part 8 Troubleshooting
260
Caution for Diagnosis
262
Troubleshooting with the Operation Lamp (RA Indoor Unit)
262
Troubleshooting with the LED on the Skyair Indoor Unit
263
Troubleshooting with the LED on the Outdoor Unit
264
Troubleshooting with the LED on the BP Unit
265
Service Check Function
266
RA Indoor Unit Infrared Remote Control
266
Skyair Indoor Unit INSPECTION/TEST Button
270
Skyair Indoor Unit Wired Remote Control
271
Skyair Indoor Unit Infrared Remote Control
272
Service Check Function
273
Sky Air Indoor Unit Error Codes and LED Indication
274
Malfunction Code Indication by Outdoor Unit PCB
275
List of Malfunction Code
279
Troubleshooting for RA Indoor Unit
281
Indoor Unit PCB Abnormality
281
Freeze-Up Protection Control or High Pressure Control
282
Fan Motor or Related Abnormality
284
Thermistor or Related Abnormality (Indoor Unit)
287
Shutter Drive Motor / Shutter Limit Switch Abnormality
288
Check
289
Thermistor Resistance Check
290
Hall IC Check
291
Troubleshooting for Skyair Indoor Unit
292
Indoor Unit PCB Abnormality
292
Malfunction of Drain Water Level System (Float Type)
293
Malfunction of Drain System
295
Indoor Unit Fan Motor Lock
296
Malfunction of Indoor Unit Fan Motor
297
Swing Flap Motor Malfunction / Lock
299
Malfunction of Capacity Setting
301
Malfunction of Heat Exchanger Thermistor (R2T)
302
Malfunction of Heat Exchanger Thermistor (R3T)
303
Malfunction of Suction Air Thermistor
304
Malfunction of Remote Control Thermistor
305
Transmission Error (between Indoor Unit and Remote Control)
306
Transmission Error (between Main and Sub Remote Control)
307
Malfunction of Field Setting Switch
308
Check
309
Troubleshooting for BP Unit
311
Malfunction of Electronic Expansion Valve
311
Faulty BP Unit PCB
312
Faulty BP Liquid or Gas Pipe Thermistor
313
Transmission Error between Indoor Unit and BP Unit
314
Transmission Error between Outdoor Unit and BP Unit
316
Check
317
Daikin Super Multi NX FDXS25EAVMB Service Manual (341 pages)
Inverter Multi for 2 Rooms G-Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 19.3 MB
Table of Contents
Table of Contents
3
Introduction
7
Safety Cautions
7
Used Icons
11
Part 1 List of Functions
12
Functions
13
Cooling Only
13
Function and Control Part
15
Heat Pump
16
Part 2 Specifications
21
Specifications
22
Cooling Only - Indoor Unit
22
Cooling Only - Outdoor Unit
29
Heat Pump - Indoor Unit
31
Heat Pump - Outdoor Unit
40
Part 3 Printed Circuit Board Connector Wiring Diagram
42
Indoor Unit
43
Wall Mounted Type
43
Floor Standing Type
51
Floor / Ceiling Suspended Dual Type
53
Duct Connected Type
55
Ceiling Mounted Cassette Type
57
Remote Controller
59
Wired Remote Controller
59
Wireless Remote Controller
60
Outdoor Unit
61
2Mk(X)S40/50Gv1B, 2Mk(X)S40/50G2V1B
61
Part 4 Function and Control
63
Function of Indoor Unit (RA Models)
64
Temperature Control
64
Frequency Principle
64
Operation Starting Control
66
Airflow Direction Control
67
Fan Speed Control for Indoor Units
69
Program Dry Operation
70
Automatic Operation
71
Thermostat Control
72
NIGHT SET Mode
74
ECONO Operation
75
HOME LEAVE Operation
76
2-Area INTELLIGENT EYE Operation
77
INTELLIGENT EYE Operation
79
Inverter POWERFUL Operation
80
Other Functions
82
Function of Indoor Unit (SA Models)
84
Drain Pump Control
84
Thermostat Sensor in Remote Controller
86
Freeze Prevention Control
88
Hot Start Control (in Heating Operation Only)
89
Function of Thermistor
90
Control Specification
92
Mode Hierarchy
92
Frequency Control
94
Controls at Mode Changing / Start-Up
97
Discharge Pipe Temperature Control
98
Compressor Protection Function
98
Input Current Control
99
Freeze-Up Protection Control
99
Heating Peak-Cut Control
100
Outdoor Fan Control
100
Liquid Compression Protection Function
101
Defrost Control
101
Electronic Expansion Valve Control
102
Malfunctions
106
Part 5 Operation Manual
109
System Configuration
110
RA Indoor Unit
111
FTXG-J, CTXG-J Series - ARC466A1
111
Fan Operation
115
Operating Conditions
116
FTXS, FVXS Series - ARC452A1, A3
133
Names of Parts
137
Opening the Front Panel
137
FTXG-E, CTXG-E, FLK(X)S, FDK(X)S Series
160
Arc433B41, B67, B68, B69, B76
160
FTXG-E, CTXG-E, FLK(X)S, FDK(X)S Series ARC433B41, B67, B68, B69, B76
160
Adjusting the Air Flow Direction
166
SA Indoor Unit - FFQ Series
179
Brc1D528
179
Brc7E530W/531W
194
Names and Functions
195
Operation Range
197
Operation Procedure
198
Part 6 Service Diagnosis
206
Troubleshooting with LED
208
Indoor Unit
208
Outdoor Unit
209
Problem Symptoms and Measures
210
Service Check Function
211
SA Indoor Unit - FFQ Series
220
RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLK(X)S
224
FDK(X)S Series
224
Code Indication on Remote Controller
224
RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLK(X)S, FDK(X)S Series
224
SA Indoor Unit - FFQ Series
224
Outdoor Unit
225
Troubleshooting for RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLK(X)S, FDK(X)S Series
226
Indoor Unit PCB Abnormality
226
Freeze-Up Protection Control or Heating Peak-Cut Control
227
Fan Motor or Related Abnormality
229
Thermistor or Related Abnormality (Indoor Unit)
232
Front Panel Open / Close Fault (FTXG, CTXG)
233
Troubleshooting for SA Indoor Unit - FFQ Series
234
Indoor Unit PCB Abnormality
234
Drain Water Level System Abnormality
235
Fan Motor or Related Abnormality
237
Drain System Abnormality
238
Thermistor or Related Abnormality
239
Remote Controller Thermistor Abnormality
241
Signal Transmission Error
242
(Between Indoor Unit and Remote Controller)
242
Signal Transmission Error (between Indoor Unit and Remote Controller)
242
Signal Transmission Error
243
(Between MAIN Remote Controller and SUB Remote Controller)
243
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
243
Field Setting Abnormality
244
Troubleshooting for Outdoor Unit
246
Anti-Icing Control for Indoor Unit
246
OL Activation (Compressor Overload)
248
Compressor Lock
249
DC Fan Lock
250
Input Overcurrent Detection
251
Discharge Pipe Temperature Control
252
High Pressure Control in Cooling
253
Compressor Sensor System Abnormality
254
Position Sensor Abnormality
255
DC Voltage / Current Sensor Abnormality
257
Thermistor or Related Abnormality (Outdoor Unit)
258
Electrical Box Temperature Rise
260
Radiation Fin Temperature Rise
261
Output Overcurrent Detection
263
Refrigerant Shortage
265
Low-Voltage Detection or Over-Voltage Detection
267
Outdoor Unit PCB Abnormality or Signal Transmission Error
268
Unspecified Voltage (between Indoor Unit and Outdoor Unit) / Anti-Icing Control in Other Room
271
Check
272
Thermistor Resistance Check
272
Fan Motor Connector Output Check
273
Hall IC Check
273
Power Supply Waveforms Check
273
Electronic Expansion Valve Check
274
Four Way Valve Performance Check
275
Inverter Unit Refrigerant System Check
276
Inverter Checker" Check
277
Rotating Pulse Input on the Outdoor Unit PCB Check
279
Installation Condition Check
280
Discharge Pressure Check
280
Outdoor Unit Fan System Check
281
Main Circuit Short Check
281
Power Module Check
282
Advertisement
Daikin Super Multi NX FDXS25EAVMB Service Manual (355 pages)
super multi nx
Brand:
Daikin
| Category:
Air Conditioner
| Size: 15.37 MB
Table of Contents
Table of Contents
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
12
List of Functions
13
Cooling Only Models
13
Heat Pump Models
18
Part 2 Specifications
24
Indoor Units - Cooling Only
25
Outdoor Units - Cooling Only
34
Indoor Units - Heat Pump
35
Outdoor Units - Heat Pump
46
Part 3 Printed Circuit Board Connector Wiring Diagram
48
Printed Circuit Board Connector Wiring Diagram
49
Wall Mounted Type
49
Duct Connected Type
58
Floor / Ceiling Suspended Dual Type
60
Floor Standing Type
63
Ceiling Suspended Type
65
Outdoor Units
67
Part 4 Function and Control
70
Main Functions
71
Frequency Principle
71
Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing
73
Operation Starting Control
75
Fan Speed Control for Indoor Units
76
Programme Dry Function
77
Automatic Operation
78
Thermostat Control
79
Night Set Mode
80
ECONO Mode
81
INTELLIGENT EYE (Wall Mounted Type Only)
82
HOME LEAVE Operation
84
Inverter POWERFUL Operation
85
Other Functions
86
Function of Main Structural Parts
88
Main Structural Parts
88
Function of Thermistor
89
Control Specification
93
Mode Hierarchy
93
Frequency Control
94
Controls at Mode Changing / Start-Up
97
Compressor Protection Function
98
Discharge Pipe Control
99
Input Current Control
99
Freeze-Up Protection Control
100
Heating Peak-Cut Control
100
Fan Control
101
Liquid Compression Protection Function 2
101
Defrost Control
102
Electronic Expansion Valve Control
103
Malfunctions
107
Forced Operation Mode
108
Wiring-Error Check
109
Additional Function
111
Part 5 Operation Manual
114
System Configuration
115
Operation Instructions
115
Instruction
116
FTK(X)S, FTXG, CTXG, FDK(X)S, FLK(X)S Series
116
Safety Precautions
117
FVXS Series
192
Air Flow Selection
203
FHQ Series
223
Temperature Setting
229
Fan Speed Control
229
Part 6 Service Diagnosis
236
Caution for Diagnosis
237
Troubleshooting with Operation Lamp
237
Problem Symptoms and Measures
239
Service Check Function
240
Check Method 1
240
Check Method 2
242
Code Indication on the Remote Control
244
Error Codes and Description of Fault
244
Troubleshooting
245
Indoor Units
245
Outdoor Units
246
Indoor Unit PCB Abnormality
247
Freeze-Up Protection Control or High Pressure Control
248
Fan Motor or Related Abnormality
250
Thermistor or Related Abnormality (Indoor Unit)
253
Front Panel Open / Close Fault
254
Signal Transmission Error (between Indoor and Outdoor Unit)
255
Unspecified Voltage (between Indoor and Outdoor Units)
257
Freeze-Up Protection Control
258
Outdoor Unit PCB Abnormality
260
OL Activation (Compressor Overload)
261
Compressor Lock
262
DC Fan Lock
263
Input over Current Detection
264
Discharge Pipe Temperature Control
266
High Pressure Control in Cooling
267
Compressor Sensor System Abnormality
269
Position Sensor Abnormality
271
CT or Related Abnormality
272
Thermistor or Related Abnormality (Outdoor Unit)
274
Sienbe12
275
Electrical Box Temperature Rise
276
Radiation Fin Temperature Rise
278
Output over Current Detection
280
Insufficient Gas
282
Low-Voltage Detection or Over-Voltage Detection
284
Signal Transmission Error (on Outdoor Unit PCB)
285
Anti-Icing Function in Other Rooms / Unspecified Voltage
286
(Between Indoor and Outdoor Units)
286
Anti-Icing Function in Other Rooms / Unspecified Voltage (between Indoor and Outdoor Units)
286
Check
287
How to Check
287
Electronic Expansion Valve Check
288
Four Way Valve Performance Check
289
Installation Condition Check
291
Discharge Pressure Check
292
Power Supply Waveforms Check
293
Capacitor Voltage Check
294
Power Transistor Check
294
Main Circuit Electrolytic Capacitor Check
295
Hall IC Check
296
Daikin Super Multi NX FDXS25EAVMB Service Manual (289 pages)
Inverter Multi for 2 Rooms
Brand:
Daikin
| Category:
Air Conditioner
| Size: 14.04 MB
Table of Contents
Table of Contents
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
11
List of Functions
12
Cooling Only Models
12
Heat Pump Models
17
Part 2 Specifications
24
Specifications
25
Indoor Units - Cooling Only
25
Duct Connected Type
27
Floor Standing Type
29
Ceiling Mounted Cassette Type
30
Outdoor Units - Cooling Only
31
Indoor Units - Heat Pump
33
Outdoor Units - Heat Pump
43
Part 3 Printed Circuit Board Connector Wiring Diagram
45
Printed Circuit Board Connector Wiring Diagram
46
Wall Mounted Type
46
Duct Connected Type
53
Floor / Ceiling Suspended Dual Type
55
Floor Standing Type
58
Ceiling Mounted Cassette Type (600×600)
60
Outdoor Units
63
Part 4 Function and Control
65
Main Functions
66
Temperature Control
66
Frequency Principle
66
Power-Airflow Flaps, Wide-Angle Louvers, Auto-Swing, COMFORT AIRFLOW Mode and 3-D Airflow
68
Operation Starting Control
70
Fan Speed Control for Indoor Units
71
Program Dry Function
73
Automatic Operation
74
Thermostat Control
75
Night Set Mode
76
ECONO Mode
77
Area Intelligent Eye (Ftxs)
78
Intelligent Eye (Atxs, Ftxg, Atxg, Ctxg)
80
HOME LEAVE Operation
82
Inverter POWERFUL Operation
83
Other Functions
84
Weekly Timer Operation
85
Function of Thermistor
86
Heat Pump Model
86
Cooling Only Model
88
Control Specification
89
Mode Hierarchy
89
Frequency Control
90
Controls at Mode Changing / Start-Up
93
Compressor Protection Function
94
Discharge Pipe Temperature Control
95
Input Current Control
95
Freeze-Up Protection Control
96
Heating Peak-Cut Control
96
Fan Control
97
Liquid Compression Protection Function 2
97
Defrost Control
98
Electronic Expansion Valve Control
99
Malfunctions
103
Additional Function
104
Part 5 Operation Manual
105
System Configuration
106
Operation Instructions
106
Instruction
107
ATXS, ATX, FTXG, CTXG, ATXG, FDK(X)S, FLK(X)S Series
107
Remote Controller
108
Adjusting the Airflow Direction
115
Adjusting the Air Flow Direction
119
Comfort Airflow Operation
123
Powerful Operation
124
Outdoor Unit Quiet Operation
125
Econo Operation
126
Intelligent Eye Operation
130
Timer Operation
134
To Use on Timer Operation
135
Note for Multi System
136
FTXS, FVXS Series
138
Comfort Airflow and Intelligent Eye Operation
147
Quiet Operation
151
FFQ Series
162
Safety Considerations
164
Installation Site
165
Operation Range
165
Switch and Display on the Remote Controller
166
Operation Procedure
166
Trouble Shooting
172
Part 6 Service Diagnosis
173
Caution for Diagnosis
174
Problem Symptoms and Measures
176
Service Check Function
177
ARC433 Series
177
ARC452 Series
180
Troubleshooting
183
Error Codes and Description
183
Indoor Unit PCB Abnormality
184
Freeze-Up Protection Control or High Pressure Control
185
Fan Motor or Related Abnormality
187
Thermistor or Related Abnormality (Indoor Unit)
191
Front Panel Open / Close Fault
192
Freeze-Up Protection Control
193
OL Activation (Compressor Overload)
195
Compressor Lock
196
DC Fan Lock
197
Input Overcurrent Detection
198
Discharge Pipe Temperature Control
200
High Pressure Control in Cooling
201
Compressor Sensor System Abnormality
203
Position Sensor Abnormality
204
DC Voltage / DC Current Sensor Abnormality
206
Thermistor or Related Abnormality (Outdoor Unit)
207
Electrical Box Temperature Rise
209
Radiation Fin Temperature Rise
211
Output Overcurrent Detection
213
Refrigerant Shortage
215
Over-Voltage Detection / Low-Voltage Detection
217
Anti-Icing Function in Other Rooms / Unspecified Voltage (between Indoor and Outdoor Units)
218
Outdoor Unit PCB Abnormality or Signal Transmission Circuit Abnormality
219
Check
222
How to Check
222
Electronic Expansion Valve Check
223
Four Way Valve Performance Check
224
Thermistor Resistance Check
225
Installation Condition Check
226
Discharge Pressure Check
227
Power Supply Waveforms Check
227
Power Transistor Check
228
Hall IC Check
231
Daikin Super Multi NX FDXS25EAVMB Service Manual (267 pages)
Inverter Multi for 2 Rooms H-Series / G-Series
Brand:
Daikin
| Category:
Heat Pump
| Size: 13.95 MB
Table of Contents
Table of Contents
3
Introduction
7
Safety Cautions
7
Used Icons
11
Part 1 List of Functions
12
Functions
13
Function and Control Part
15
Part 2 Specifications
21
Indoor Unit
22
Specifications
23
Floor Standing Type
33
Duct Connected Type
36
Ceiling Mounted Cassette Type
37
Outdoor Unit
38
Part 3 Printed Circuit Board Connector Wiring Diagram
39
Indoor Unit
40
Ftxg25/35/50Jv1Bw(S)(A)
40
Ctxs15/35K2V1B, Ftxs20/25K2V1B
42
Ftxs35/42/50K2V1B, Ftxs20/25/35/42/50J2V1B, Atxs20/25/35/42/50G2V1B
44
Ftx20/25/35Jv1B, Ftx20/25/35J2V1B, Atx20/25/35Jv1B, Atx20/25/35J2V1B
46
Fvxg25/35/50K2V1B
48
Fvxs25/35/50Fv1B
50
Flxs25/35/50Bavmb
52
Fdxs25/35Eavmb, Fdxs25/35E7Vmb, Fdxs50Cvmb, Fdxs50C7Vmb
54
Ffq25/35/50B8V1B, Ffq25/35/50B9V1B
56
Wired Remote Controller
57
Brc1D528
57
Brc1E51A7
58
Wireless Remote Controller
59
Brc7E530W
59
Outdoor Unit
60
Part 4 Function and Control
62
Function of RA Indoor Unit
63
Temperature Control
63
Frequency Principle
63
Operation Starting Control
65
Airflow Direction Control
66
Fan Speed Control for Indoor Unit
69
RADIANT Operation
71
Program Dry Operation
73
Automatic Operation
74
Thermostat Control
75
NIGHT SET Mode
76
ECONO Operation
77
HOME LEAVE Operation
78
2-Area INTELLIGENT EYE Operation
80
INTELLIGENT EYE Operation
82
Inverter POWERFUL Operation
83
Multi-Colored Indicator Lamp / TIMER Lamp
84
Brightness Setting of Indoor Unit Display
85
Clock Setting
86
WEEKLY TIMER Operation
87
Other Functions
93
Function of SA Indoor Unit
94
Drain Pump Control
94
Remote Controller
95
Thermostat Sensor in Remote Controller
96
Freeze Prevention Control
98
Hot Start Control (in Heating Operation Only)
99
Function of Thermistor
100
Control Specification
102
Mode Hierarchy
102
Frequency Control
103
Controls at Mode Changing / Start-Up
105
Discharge Pipe Temperature Control
106
Input Current Control
107
Freeze-Up Protection Control
107
Heating Peak-Cut Control
108
Outdoor Fan Control
109
Liquid Compression Protection Function
109
Defrost Control
110
Outdoor Electronic Expansion Valve Control
111
Malfunctions
115
Part 5 Remote Controller
117
RA Indoor Unit
118
Ftxg25/35/50Jv1Bw(S)(A), Ctxs15/35K2V1B, Ftxs20/25K2V1B
118
Mode Button
119
Ftxs35/42/50K2V1B
120
Ftxs20/25/35/42/50J2V1B
122
Atxs20/25/35/42/50G2V1B
124
Ftx20/25/35Jv1B, Ftx20/25/35J2V1B, Atx20/25/35Jv1B, Atx20/25/35J2V1B
126
Fvxg25/35/50K2V1B
128
Fvxs25/35/50Fv1B
130
Flxs25/35/50Bavmb
132
Fdxs25/35Eavmb, Fdxs25/35E7Vmb, Fdxs50Cvmb, Fdxs50C7Vmb
134
SA Indoor Unit
136
Brc1D528
136
Brc1E51A7
139
Operation Mode
142
Brc7E530W
144
Part 6 Service Diagnosis
145
Troubleshooting with LED
147
Indoor Unit
147
Outdoor Unit
148
Problem Symptoms and Measures
149
Service Check Function
150
RA Indoor Unit
150
Arc452 Series Remote Controller
153
Arc433 Series Remote Controller
156
SA Indoor Unit
159
Code Indication on Remote Controller
166
RA Indoor Unit
166
SA Indoor Unit
166
Outdoor Unit
167
Troubleshooting for RA Indoor Unit
168
Indoor Unit PCB Abnormality
168
Freeze-Up Protection Control or Heating Peak-Cut Control
170
Fan Motor or Related Abnormality
172
Radiant Panel Temperature Rise, Indoor Electronic Expansion Valve (Motor Operated Valve) Abnormality, Freeze-Up Protection Control (FVXG Series Only)
176
Thermistor or Related Abnormality (RA Indoor Unit)
178
Front Panel Open / Close Fault (FTXG Series Only)
179
Troubleshooting for SA Indoor Unit
180
Indoor Unit PCB Abnormality
180
Drain Level Control System Abnormality
181
Fan Motor (AC Motor) or Related Abnormality
182
Drain System Abnormality
183
Thermistor or Related Abnormality (SA Indoor Unit)
184
Remote Controller Thermistor Abnormality
185
Signal Transmission Error (between Indoor Unit and Remote Controller)
186
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
187
Field Setting Abnormality
188
Troubleshooting for Outdoor Unit
189
Refrigerant Shortage
189
Low-Voltage Detection or Over-Voltage Detection
191
Outdoor Unit PCB Abnormality or Signal Transmission Error
193
Unspecified Voltage (between Indoor Unit and Outdoor Unit) / Anti-Icing Control in Other Room
196
Anti-Icing Control for Indoor Unit
197
OL Activation (Compressor Overload)
199
Compressor Lock
201
DC Fan Lock
202
Input Overcurrent Detection
203
Discharge Pipe Temperature Control
204
High Pressure Control in Cooling
205
Compressor Sensor System Abnormality
206
Position Sensor Abnormality
207
DC Voltage / Current Sensor Abnormality
209
Thermistor or Related Abnormality (Outdoor Unit)
210
Electrical Box Temperature Rise
212
Radiation Fin Temperature Rise
213
Output Overcurrent Detection
215
Check
217
Thermistor Resistance Check
217
Fan Motor Connector Output Check
218
Hall IC Check
219
Indoor Electronic Expansion Valve Coil Check
219
Power Supply Waveforms Check
220
Outdoor Electronic Expansion Valve Check
221
Four Way Valve Performance Check
222
Inverter Unit Refrigerant System Check
222
Inverter Analyzer Check
223
Rotating Pulse Input on the Outdoor Unit PCB Check
225
Installation Condition Check
226
Discharge Pressure Check
226
Outdoor Unit Fan System Check
227
Main Circuit Short Check
227
Power Module Check
228
DAIKIN Super Multi NX FDXS25EAVMB Operation Manual (28 pages)
Inverter
Brand:
DAIKIN
| Category:
Air Conditioner
| Size: 2.51 MB
Table of Contents
Operation Manual
1
Table of Contents
2
Safety Precautions
3
Installation Site
4
Electrical Work
4
Names of Parts
5
Outdoor Unit
6
Indoor Unit
6
Remote Controller
7
Preparation before Operation
8
AUTO · DRY · COOL · HEAT · FAN Operation
11
To Change the Air Flow Rate Setting
12
POWERFUL Operation
13
OUTDOOR UNIT QUIET Operation
14
HOME LEAVE Operation
15
TIMER Operation
17
To Use on Timer Operation
18
To Combine on Timer and off Timer
18
Note for Multi System
19
Care and Cleaning
21
Before a Long Idle Period
22
Trouble Shooting
23
Check Again
24
Call the Service Shop Immediately
25
Disposal Requirements
25
Important Information Regarding the Refrigerant Used
25
Fault Diagnosis
26
Daikin Super Multi NX FDXS25EAVMB Installation Manual (15 pages)
R410A Split Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.84 MB
Table of Contents
Safety Precautions
3
Choosing a Site
4
Preparations before Installation
5
Indoor Unit Installation
7
Outdoor Unit Installation
8
Refrigerant Piping Work
8
Drain Piping Work
10
Installing the Duct
11
Trial Operation and Testing
13
Advertisement
Related Products
DAIKIN FDXS25F2VEB
DAIKIN FDXS25E7VMB
Daikin Inverter FDXS25CVMB
Daikin FDXS25CVMA
Daikin FDXS25CAVMB
Daikin FDXS25LVMA
Daikin FDXS25CVMB FDKS25CVMB FDXS35CVMB FDKS35CVMB CDXS50CVMB
DAIKIN Super Multi NX FDXS60CVMB
DAIKIN FDXS60F2VEB
Daikin FDXS50F2VEB9
DAIKIN Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More DAIKIN Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL