Sign In
Upload
Manuals
Brands
BINMASTER Manuals
Monitor
Large Modbus DPM-300
BINMASTER Large Modbus DPM-300 Manuals
Manuals and User Guides for BINMASTER Large Modbus DPM-300. We have
1
BINMASTER Large Modbus DPM-300 manual available for free PDF download: Instruction Manual
BINMASTER Large Modbus DPM-300 Instruction Manual (78 pages)
Brand:
BINMASTER
| Category:
Monitor
| Size: 4 MB
Table of Contents
Table of Contents
3
Table of Figures
4
Introduction
5
Ordering Information
5
Specifications
6
Operating Modes
6
Master & Snooper Settings
6
PV Settings
6
Display Settings
6
Math Functions
7
Serial Communications
7
General
7
Relays
8
Isolated 4-20 Ma Transmitter Output
8
Dual Process Input
9
Digital Input & Output Terminal
9
Compliance Information
9
Safety
9
Safety Information
10
Installation
10
Unpacking
10
Wall Mounting Instructions
11
Mounting Dimensions
11
Figure 1. Meter Mounting Holes
11
Figure 2. Meter Dimensions - Side View
11
Figure 3. Meter Dimensions - Front View
11
Pipe Mounting Instructions
12
Figure 4. Vertical Pipe Mount Assembly
12
Figure 5. Horizontal Pipe Mount Assembly
12
Transmitter Supply Voltage Selection (P+, P-)
13
Connections
13
Figure 6. Transmitter Supply Voltage Selection
13
Connectors Labeling
14
Power Connections
14
Figure 7. Connector Labeling for Fully Loaded
14
Figure 8. Power Connections
14
Serial Communications Connection
15
Figure 9. RS485 Connection
15
Figure 10. RS-422 or RS-485 Wiring
15
Figure 11. RS-485 Two-Wire Multi-Drop Wiring
16
Figure 12. Connections for RS485 Connector to Serial Converter
16
Figure 13. Three-Wire RS485 Connection
16
Digital I/O Connections
17
F4 Digital Input Connections
17
Figure 14. Digital Input and Output Connections
17
Figure 15. F4 Digital Input Connections
17
Relay Connections
18
Switching Inductive Loads
18
Figure 16. Relay Connections
18
Figure 17. AC and DC Loads Protection
18
Figure 18. Low Voltage DC Loads Protection
18
4-20 Ma Output Connections
19
Analog Output Transmitter Power Supply
19
Interlock Relay Feature
19
External Analog Output Connection
19
Figure 19. 4-20 Ma Output Connections
19
Figure 20. Interlock Connections
19
Analog Input Signal Connections
20
Figure 21. Transmitters Powered by Internal Supply
20
Figure 22. Transmitter Powered by Ext. Supply or Self-Powered
20
Figure 23. Voltage Input Connections
20
Setup and Programming
21
Overview
21
Programming Buttons and Status LED Indicators
22
Scanview Software
23
Scanview Installation
23
Display Functions & Messages
24
Main Menu
28
Menu Navigation Tip
28
Setting Numeric Values
28
Serial Communications (Serial)
29
Scanner Mode Selection
30
Operating Modes (Nmode)
30
How to Enable Process Variables (Pvs)
30
Master Mode (Nmastr)
31
Snooper Mode (Snoopr)
32
Slave Mode (Slave)
33
Setting up the Scanner (Setup)
34
Setting up the Process Variables (Pvs) (Pv Setup)
34
Setting the Display Decimal Point (Disp. D P)
35
Setting the Float Decimal Point (Flot
35
Scaling the PV Display Values (Scale)
35
Scale Menu
35
Setting up the Displays (Dsplay Setup)
36
Display Line 1 Parameters (Line 1 Dsplay)36
36
Display Line 2 Parameters (Line 2 Dsplay)36
36
Display Intensity (D-Inty)
36
Display Line 1 Menu (Line 1 Dsplay)
37
Display Line 2 Menu (Line 2 Dsplay)
38
Setting the Tags (Tag) & Units (Units)
39
Application Example 1
39
Application Example 2
42
Setting the Relay Operation (Relay)
43
Setting the Relay Action
44
Programming Set and Reset Points
44
Setting Fail-Safe Operation
44
Programming Time Delay
44
Relay Action for Communications Break (Break)
44
Relay Action for Loss of 4-20 Ma Input (Loop Break)
44
Relay and Alarm Operation Diagrams
45
High Alarm Operation (Set > Reset)
45
Low Alarm Operation (Set < Reset)
45
High Alarm with Fail-Safe Operation (Set > Reset)
46
Low Alarm with Fail-Safe Operation (Set < Reset)
46
Pump Alternation Control Operation
46
Relay Sampling Operation
47
Signal Loss or Loop Break Relay Operation
47
Time Delay Operation
47
Relay Operation Details
48
Overview
48
Relays Auto Initialization
48
Fail-Safe Operation
48
Front Panel Leds
48
Latching and Non-Latching Relay Operation
49
Non-Latching Relay (Auto)
49
Non-Latching Relay (A-Man)
49
Latching Relay (Latch)
49
Latching Relay (Lt-Clr)
49
Acknowledging Relays
50
Pump Alternation Control Applications (Altern)
50
Figure 24. Acknowledge Relays W/Function Key or Digital Input
50
Setting up the Interlock Relay (Force On) Feature
51
Scaling the 4-20 Ma Analog Output (Aout)
52
Setting up the Password (Pass)
53
Protecting or Locking the Meter
53
Making Changes to a Password Protected Meter
53
Disabling Password Protection
53
Advanced Features Menu
54
Advanced Menu Navigation Tips
54
Advanced Features Menu & Display Messages55
55
Scan Function (Scan)
58
Control Menu (Contrl)
59
Noise Filter (Filter)
59
Noise Filter Bypass (Bypass)
59
Rounding Feature (Round)
59
Select Menu (Select)
60
Input Data Conditioning Function Menu (Functn)
60
Linear Function Menu (Linear)
61
Square Root Function Menu (Square)
61
Programmable Exponent Function Menu (Prog E)
61
Round Horizontal Tank Function Menu (Rht)
62
Math Functions (Math)
63
Low-Flow Cutoff (Cutoff)
67
Analog Output Programming (Aoutpr)
68
User Menu (User)
69
Digital Input Menu (DI 1)
70
Digital Output Menu (Do 1)
70
Reset Menu (Reset)
70
4-20 Ma Output Calibration
71
Internal Source Calibration (ICAL)
71
Scanner Operation
73
Button Operation
73
Function Key Operation
73
Digital Input Operation
73
Maximum/Minimum Readings
74
Troubleshooting
74
Diagnostics Menu (Diag)
74
Determining Software Version
74
Reset Scanner to Factory Defaults
74
Testing the Display Leds
74
Factory Defaults & User Settings
75
Troubleshooting Tips
77
Advertisement
Advertisement
Related Products
BINMASTER DPM-100
BINMASTER DPM-200
BINMASTER DPM-500
BINMASTER DPM-400
BINMASTER Categories
Measuring Instruments
Accessories
Gateway
Security Sensors
Switch
More BINMASTER Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL