2. Insert and turn the hexagonal shaft at the top of the mount arm into the slot on the wall plate (
3. Insert and turn the M8 hexagon bolt at the bottom of the mount arm into the wall plate (
Caution
❏
Make sure the Touch Unit connection cable is not wired into the wall with the other cables.
❏
Take care not to trap the cables between the mount arm and wall plate.
4. Secure the mount arm to the wall plate by tightening the supplied M6 × 20 mm cross recessed head
shoulder screws (×3) with the No.3 cross-head screwdriver (
mm hexagon shoulder bolt supplied (
M6 × 20 mm cross recessed
head shoulder screws (×3)
Touch Unit connection cable
M8 hexagonal bolt
). Then, loosely tighten the M6 × 20
).
37
).
Hexagonal shaft
).