Wall Embedding - Pioneer PDP-V402 Technical Manual

Plasma display
Hide thumbs Also See for PDP-V402:
Table of Contents

Advertisement

Special installations (Wall embedding)

3.4.3 Wall embedding

This display is designed to accommodate embedding in a wall. Note that the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following requirements:
1 Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
2 Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
3 Installation conditions and ambient operating temperatures:
(1) If the back of the display will be unobstructed (If there is no obstruction within 300 mm from the backside):
A
100 mm
B
X-Y space temperature requirements
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
* When mounting the down converter (PDA-4003), the same working temperature conditions apply.
30
100 mm
A
Intake
100 mm
100 mm
A
A size
150 mm or more
X
Y
PC-9800 (56.4Hz)
VIDEO
Machintosh (66.7Hz)
0~40°C
0~40°C
MAX 20 mm
Exhaust
PC-9800 (70.1Hz)
VGA (72.8Hz, 75Hz)
VGA (60Hz)
0~40°C
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-v402e

Table of Contents