Special installations (Fixing on a structure)

3.4 Special installations

This display may be installed in several different positions, including wall-hanging and wall-embedding. Conditions,
including temperature, may restrict the use of certain positions or installation methods.
Consider installation methods and conditions, and see the description given in "3.1 to 3.3" in this chapter.
All the measurement conditions in this manual are set in conformity with the following:
• 100% white light is applied.
• After sufficient aging
All measurements should be performed under the same conditions. The aging time needed for measurement
depends on the size of the installation space, but the standard time is approximately 2.5 hours.
"Sufficient strength to withstand" means sufficient strength to withstand a weight four times that of the main body
including the metal fixture.

3.4.1 Fixing on a structure

To fix the machine on a structure, observe the following conditions:
1 When fixing on a structure, make sure to install the display in a complete open-air condition (a condition that has no
interference within a radius of 300 mm of this display).
2 After fixing on a structure, the distortion of the unit must be within 1 mm.
3 Do not block holes other than those shown blocked in the fixing figure on the next page.
4 Use a structure 20 mm or less in thickness.
(In the case of the fixing examples 1 and 4 on the next page, the thickness of the structure is not limited.)
5 If an L-shaped structure is used, the thickness of the structure must be 100 mm or less.
6 Use a structure with sufficient strength.
7 Care must be taken not to apply stress to the power cable.
* The descriptions in 2 - 7 indicate the common precautions for fixing the machine on the structure in "wall-hanging"
and "wall-embedding."
Distortion of the unit is 1mm max.
20 mm or less
in thickness
The thickness of the examples 1 and
4 on the next page is not limited.
Operating temperature requirements
When normally installed
• Ambient temperature requirement: 0 to 40°C (Examples 1 and 2)
When vertically installed
• Ambient temperature requirement: 0 to 40°C (Examples 3 and 4)
When installing speakers
For ambient temperature requirements, the same requirements as indicated above apply.
* When mounting the down converter (PDA-4003), the same working temperature conditions apply.
24
36 mm or less in width
100 mm
or less
20 mm or less
in thickness
The thickness of the examples 1 and
4 on the next page is not limited.
L-shaped structure
36 mm or less in width