Installation conditions

3.2 Installation conditions

3.2.1 Radiation

This display comes with multiple ventilation holes for efficient radiation of heat. Avoid blocking any of these holes.
Ventilation holes are indicated by arrows in the following drawing.
48.8mm
Air flows out through five of the ventilation holes and flows in through the other holes. For special installations, such
as wall-hanging or embedding, additional restrictions apply concerning operating temperature. See "3.4 Special
installations".

3.2.2 Calculating calorific values

Estimate the maximum power consumption per device as 400 W plus a safety margin. Most of the power consumed
is converted to heat, so power consumption is roughly equivalent to generated heat.
1) Conversion to calories
[W] × 0.86 = [kcal/h]
Calorific value per display
400 × 0.86 = 344 [kcal/h]
2) Conversion to British thermal unit (BTU)
[W] × 3.41 = [B.t.u./h]
Calorific value per display
400 × 3.41 = 1256 [B.t.u./h]
14
539 mm (Size of air inlet hole)
463 mm (Size of air inlet hole)
377 mm (Size of air inlet hole)
49 mm (Size of air inlet hole)
23mm
152mm (Size of air inlet hole)
160mm (Size of air inlet hole)
189.5mm (Size of air inlet hole)
858mm (Size of air inlet hole)
284.3 mm
C.L.
Exhaust fan 5 units
46mm
152mm (Size of air inlet hole)
4mm
402.4mm
916mm
82.5mm 101.5mm