REGULATORY INFORMATION

The appliance is not intended for use by young children or the infi rm person without supervision. Young
children should be supervised to ensure that they do not play with the appliance.
E nvironmental Requirements
E
nvironmental Requirements
Environmental Requirements
Battery Disposal
The batteries must be recycled or disposed of properly.
End-of-Life Disposal
End-of-Life Disposal
End-of-Life Disposal
"Instructions for end-user" for air conditioners:
This air conditioner bears the above mark, indicating that electrical equipment should not be disposed
of alongside general household waste. European Community countries (*), should have a dedicated
collection system for these products. Do not try to dismantle the system yourself as this could have harmful
effects on your health and on the environment as a result of incorrect waste handling. This dismantling
and disposal of refrigerant, oil and other parts must be done by a qualifi ed installer in accordance with
relevant local and national regulations. Air conditioners must be treated at a specialized treatment facility
for re-use, recycling and recovery and should not be disposed of in the municipal waste stream. Please
contact your installer, dealer or local authority for more information. Penalties may also be applicable for
incorrect disposal of waste products, in accordance with national legislation.
*subject to the national law of each member state
Information on Disposal in other countries outside the European Union
This symbols in only valid in the European Union. If you wish to discard this product, please contact
your installer, dealer or local authority and ask for the correct method of disposal.
Replacement or installation of power plugs shall be performed by authorized/qualifi ed
personnel only.The wires in this mains lead are coloured in accordance with the
following code:
Terminals
red
black
green/yellow
Wiring colour codes may vary from depending on country.
wires
colours
(GB Standard)
live
brown
neutral
blue
earth
green-yellow

Operation Condition

Use this air conditioner under the
following temperature range.
Indoor
Temperature (°C)
*DBT *WBT
Maximum
32
COOLING
Minimum
16
Maximum
30
HEATING
Minimum
16
Outdoor
Temperature (°C)
*DBT *WBT
Maximum
43
COOLING
Minimum
-15
Maximum
24
HEATING
Minimum
-15
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
• This unit is still able to operate as a
cooler with outdoor temperature as
low as -15°C in a non-living room,
such as a computer room, with a
room temperature of 16°C or above,
and room humidity up to 80%.
• When the outdoor temperature drops
to -15°C, compressor will be cut off
and resume operation again once
the temperature rises to more than
-15°C.
Note:
The illustrations in this manual
are for explanation purposes only
and may differ from the actual unit. It
is subjected to change without notice
for future improvement.
23
11
26
18
3