The storage system monitors conditions at different points within each enclosure to alert you to problems.
Power, cooling fan, temperature, and voltage sensors are located at key points in the enclosure. In each
controller module and expansion module, the enclosure management processor (EMP) monitors the status
of these sensors to perform SCSI enclosure services (SES) functions.
The following sections describe each element and its sensors.

Power supply sensors

Each enclosure has two fully redundant power supplies with load-sharing capabilities. The power supply
sensors described in the following table monitor the voltage, current, temperature, and fans in each power
supply. If the power supply sensors report a voltage that is under or over the threshold, check the input
voltage.
Table 18 Power supply sensor descriptions
Description
Power supply 1
Power supply 2

Cooling fan sensors

Each power supply includes two fans. The normal range for fan speed is 4,000 to 6,000 RPM. When a
fan speed drops below 4,000 RPM, the EMP considers it a failure and posts an alarm in the storage system
event log. The following table lists the description, location, and alarm condition for each fan. If the fan
speed remains under the 4,000 RPM threshold, the internal enclosure temperature may continue to rise.
Replace the power supply reporting the fault.
Table 19 Cooling fan sensor descriptions
Description
Fan 1
Fan 2
Fan 3
Fan 4
During a shutdown, the cooling fans do not shut off. This allows the enclosure to continue cooling.

Temperature sensors

Extreme high and low temperatures can cause significant damage if they go unnoticed. Each controller
module has six temperature sensors. Of these, if the CPU or FPGA (Field-programmable Gate Array)
temperature reaches a shutdown value, the controller module is automatically shut down. Each power
supply has one temperature sensor.
54
Troubleshooting
Event/Fault ID LED condition
Voltage, current, temperature, or fan fault
Voltage, current, temperature, or fan fault
Location
Event/Fault ID LED condition
Power supply 1
< 4,000 RPM
Power supply 1
< 4,000 RPM
Power supply 2
< 4,000 RPM
Power supply 2
< 4,000 RPM