NOTE: If the print pad is out of range, you will have to
perform a manual adjustment .
4 .
Remove the print pad and select the
NOTE: To remove it, lift up the front of the print pad and pull it
out of the printer . The print pad is magnetically attached to the
adjustment knobs .
5 .
When prompted, loosen the lock screw that is indicated on the
touchscreen display . Select the
NOTE: Use the 1 .5mm Allen wrench that is included with the
printer .
NOTE: The lock screw (1) is located just below the adjustment
knob (2) . The lock screw for adjustment knob B can be
accessed from the front of the printer . The lock screw for
adjustment knob A can be accessed from behind the printer .
6 .
Follow the instructions on the touchscreen display . When finished
making the adjustments, select the
7 .
When prompted, tighten the lock screw enough to ensure the
adjustment knob does not easily turn . Select the
continue .
Caution: Do not over-tighten the lock screw . This can damage
the adjustment knob and void the manufacturer's warranty .