Stepping Motor Driving(12)
1
2
MICOM
3
4
DESCRIPTION
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.
It is driving as following Fig 12-1. (Ring Count Method of 8 Status)
Ø 4
Ø 3
Ø 2
Ø 1
(Normal Rotating)
12V
CN13
1
IC6
2
3
4
5
6
KID65004
Fig 12-1
87
B +
Ø 1
M1
Ø 2
FOR SWING
Ø 3
Ø 4
(Reversed Rotating)