Ignition System
Crankshaft Sensor Peak Voltage Check
To check the peak voltage, do the following procedures.
Disconnect the magneto lead connector from the main
harness.
Measure the voltage with each lead connected cor-
rectly.
The correct value may not be obtained if
disconnected.
Maintain the correct value of compression pressure for
the cylinder (Be sure to measure the voltage with the
spark plug installed to the cylinder head).
Set the hand tester to DC 10 V range.
Connect the peak voltage adapter [A] to the tester and the
terminals of the magneto lead connector [B].
Special Tools - Hand Tester: 57001-1394
Peak Voltage Adapter: 57001-1415
Type: KEK-54-9-B
Connections:
Crankshaft
Sensor Lead
Green [C]
Red [D]
Crank the engine by kicking the pedal several times to
measure the peak voltage of the crankshaft sensor.
Crankshaft Sensor Peak Voltage
Standard:
If the voltage is less than the specified, check the crank-
shaft sensor.
NOTE
Peak Voltage
Adapter
Red
Black
1.4 V or more
ELECTRICAL SYSTEM 16-17