Rear Panel - Sony XC-HR90 Technical Manual

Ccd black-and-white video camera module
Hide thumbs Also See for XC-HR90:
Table of Contents

Advertisement

Rear Panel

Note
Be sure to turn the power off before making switch
settings.
 VIDEO OUT/DC IN/SYNC (video output/DC power/sync
input signal) connector (12-pin connector)
Connect a CCXC-12P05N camera cable to this
connector to obtain power from the +12V DC
power supply and also to enable video signal output
from the camera module. When a sync signal
generator is connected to this connector, the camera
module is synchronized with the external sync
signals (HD/VD signals).
 M GAIN (Manual Gain) control knob
If you have selected MANUAL (manual adjustment)
with DIP switch
, this knob adjusts the gain.
 Shutter speed/Mode setting DIP switches
 Shutter speed (Switches 1 to 4)
Set an appropriate shutter speed (factory setting:
OFF).
 Partial scan mode switch (Switch 5)
The factory setting of this switch is partial scan
OFF.
For more information, see "Partial Scan Mode" (page 20).
VIDEO OUT/DC IN/SYNC connector
M Gain control knob
Shutter speed / mode setting DIP switches
Mode setting DIP switches
 Restart reset/External trigger shutter mode
switches (Switches 6 to 8)
By inputting an external restart/reset signal, you
can capture the information of single screens at
arbitrary timing. By inputting an external trigger
signal, you can capture imaging information on
fast-moving objects at a precise moment in time.
The factory settings for these switches are for
normal operation.
For more information, see "Restart/Reset" (page 19) and
"External Trigger Shutter" (page 22).
 Gain switch (Switch 9)
This switch selects FIX (fixed) or MANUAL
(manual adjustment) (factory setting: FIX (left
side)).
 Binning mode switch (Switch 0)
Switches the video signal output mode between
binning OFF and binning ON (factory setting:
OFF).
For more information, see "Video Output Modes" (page 14).
 Mode setting DIP switches
 75Ω termination switch
Set this switch to the down position (OFF) when
not terminating the external sync signal. Set this
switch to the up position (ON) when
terminating the external sync signal (factory
setting).