Sony TRIMASTEREL BVM-F250 Operation Manual page 68

Professional video monitor
Hide thumbs Also See for TRIMASTEREL BVM-F250:
Table of Contents

Advertisement

The OVER RANGE lamp may indicate an error or
warning. For details, see “Error/warning display by the
lamp” (page 68).
d ECO lamp
The color of the lamp changes according to the power
consumption status of the monitor. The color changes from
green to yellow to magenta in order of greater power
consumption. Decreasing the luminance of the screen by
adjusting brightness/contrast is recommended when the
lamp lights in yellow or magenta.
The lamp starts flashing rapidly approximately one minute
before the screen saver is activated. Flashing slows in
green when the screen saver starts.
The ECO lamp may indicate an error or warning. For
details, see “Error/warning display by the lamp”
(page 68).
Error/warning display by the lamp
The OVER RANGE lamp, OPERATE lamp and/or ECO
lamp on the front panel may show an error or warning
while the monitor is being operated.
If the error or warning is shown, please contact your Sony
representative.
Error display
ECO
OVER
OPERATE
Symptoms
lamp
RANGE
lamp
lamp
Lights in
Lights in
Flashes in
The power in the
yellow
amber
red
panel part is unusual.
Lights in
Flashes in
Flashes in
The temperature in
yellow
amber
red
the panel part is
unusual.
Flashes in
Lights in
Flashes in
The ambient
yellow
amber
red
temperature sensor is
unusual.
Lights in
Flashes in
Flashes in
Fan error.
magenta
amber
red
Flashes in
Lights in
Flashes in
Device error.
magenta
amber
red
Warning display
ECO
OVER
OPERATE
Symptoms
lamp
RANGE
lamp
lamp
Flashes in
The luminance is
amber
reduced to protect the
panel from an
increase of
temperature in the
panel part.
Lights in
Over range
amber
–: Status except for error display.