Bosch Carephone 50 ISA-50-MS User And Programming Manua page 31

Table of Contents

Advertisement

Carephone 50
29
Hear/speech impaired on/off
For users with speaking or hearing difficulties.
Once a connection to the social alarm call centre has been
established, a speech connection is established. If the user now
presses the emergency call button again, the word emergency
call is sent to the social alarm call centre. If the stop button is
pressed, then the user's recorded message (e.g. false alarm) is
sent to the social alarm call centre.
You program:
30
Unit ID
When an emergency call is made, this number is sent to the
emergency call recipient. The number can be up to 6 digits long.
NOTE! The numbers 0 and 9999 may not be used in the RB2000
protocol.
34
Individual voice recording
In an emergency call, a recorded message will be transmitted
instead of the unit ID. The max. message length is 6 seconds
1.
2.
3.
4.
5.
To delete your voice recording, press the A key.
To end the recording early, press the E key.
58
Registration call
Following an emergency call to a phone, a registration call can
be sent to a social alarm call centre where it will be stored in the
alarm history. The service call and technical messages do not use
this function. The call destination must be a social alarm call
centre.
The function is deactivated by selecting a blank call number or a
call number with the telephone.
Bosch Security Systems
0 = Off
1 = On (see programming step 72.)
Press D to start recording.
The unit announces This is the social alarm unit. A signal
tone introduces the recording of your message.
Speak your message.
Recording is ended with a signal tone.
Press F to play back your voice recording.
User Manual
Programming | en 31
ISA-50-MS V2 I 2008.02

Advertisement

Table of Contents
loading

Table of Contents