Demand controlled water softener

Advertisement

Table of Contents
Customizing Features / Options
s
3. Press the
UP or
number of days.
4. Press the PROGRAM button three times to return
to the normal time of day screen.
SALT EFFICIENCY
When this feature is ON, the water softener will oper-
ate at salt efficiencies of 4000 grains of hardness per
pound of salt or higher (May recharge more often
using smaller salt dosage and less water). The sof-
tener is shipped with this feature set OFF.
1. Press the PROGRAM button and hold for three
seconds, until the "Recharge Time" screen (Figure
26) is displayed.
2. Once in this display, press the PROGRAM button
twice and the display in Figure 28 is shown.
s
3. Press the
UP or
OFF. When set to ON, the efficiency icon will be
displayed in the lower left hand corner of the nor-
mal run display.
4. Press the PROGRAM button twice to return to the
normal run display.
In the state of California: You must turn the Salt
Efficiency Feature ON. This may initiate more
frequent recharges. However, it will operate at
4,000 grains per pound of salt or higher.
DOWN buttons to set the
Efficiency
icon
FIG. 28
DOWN buttons to set ON or
HEAVY DUTY BACKWASH
When set to ON, the backwash cycle of regeneration
will be 22 minutes long instead of the normal 15
minute length. This is beneficial on some water sup-
plies high in iron or sediment content. To conserve
water, when this softener is installed on clean water
supplies, be sure OFF is set.
1. Press the PROGRAM button and hold for three
seconds, until the "Recharge Time" screen (Figure
26) is displayed.
2. Once in this display, press the PROGRAM button
three times and the "Heavy Backwash" screen
(Figure 29) is displayed.
3. Press the
UP or
OFF.
4. Press the PROGRAM button once again to return
to the normal run display.
MODEL CODE
The model code is factory set at assembly and testing.
The model code should never require resetting, but to
check, or to set if previously omitted, follow the steps
below.
1. Press the PROGRAM button and hold for three
seconds, until the "Recharge Time" screen (Figure
26) is displayed.
2. Again, press the PROGRAM button and hold for
three seconds. Either "- - - -" or the previously set
code "LL60" will appear.
3. Use the
UP or
correct model code (LL60).
4. Press the PROGRAM button three times to return
to the normal time of day screen.
15
s
DOWN buttons to set ON or
s
DOWN buttons to select the
FIG. 29
FIG. 30