Quick Links

iNSTALLATiON
A ND SERVICE MUST BE PERFORMED
BY
A QUALiFiED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS
FOR FUTURE REFERENCE.
This conversion
kit must be installed by a qualified
service
technician
in accordance
with the
manufacturer's
instructions and all applicable
codes and requirements
of the authority
having jurisdiction.
Failure
to follow instructions may result in fire, explosion
or production
of carbon
monoxide
causing
property
damage,
personal
injury or loss of life. The qualified
service agency is responsible
for the proper installation ofthis
kit. The
installation is not proper and complete
until the operation
of the converted
appliance
is checked as specified
in the
manufacturer's
instructions supplied
with this kit.
Before proceeding
with the conversion,
shut offthe gas supply before disconnecting
electrical
power
to the range. Be sure both power supplies
are off before installing the conversion
kit. Failure to do so could cause
serious bodily injury.
Note: When surface
burners
are converted
from Natural to
L.P. the BTU ratings become:
5,000 BTU* Natural Gas to 4,500 BTU* L.P. Gas
6,000 BTU* Natural Gas to 6,000 BTU* L.P. Gas
9,500 BTU* Natural Gas to 8,000 BTU* L.P. Gas
17,200 BTU* Natural Gas to 14,000 BTU* L.P. Gas
L.P. Kit
Contents
Kit pin 316243718 (Peach)
Part Description
Part Number
Qty.
Surface Burner Orifice marked 0.68mm 4,500 BTU* (blue)
Surface Burner Orifice marked 0.75mm 6,000 BTU* (no color)
Surface Burner Orifice marked 0.89mm 8,000 BTU* (no color)
Surface Burner Orifice marked 1.15mm 14,000 BTU* (black)
L.P. Kit Installation Instructions
316237907
316237915
316237906
316237910
316417508
1
3
2
1
1
*Note:
For operation
at elevations
above
2000 ft., appliance
rating
shall be reduced
at the rate of 4 percent
for each 1000 ft. above sea
level,
How to Convert
the Range
for use with LP/
Propane
Gas
1.
Convert
the Pressure
Regulator
(complete this step
for ALL models):
To access the gas regulator, remove the storage drawer or Warmer
Drawer. If equipped with a storage drawer, open & remove the drawer
completely.
For models equipped with a Warmer Drawer, follow the
instructions below to remove the Warmer Drawer.
a.
_
Electrical Shock Hazard can occur and result in
serious injury or death. Disconnect
electrical power to the range
before removing the Warmer Drawer for servicing.
b.
Locate glide lever on each side of drawer, pull up on the left glide
lever and push down on the right glide lever (See Fig. 1).
c.
Pull the Warmer Drawer away from the range (See Fig. 2).
d.
Remove the regulator access cover if equipped. Do not remove the
Pressure
Regulator
or allow it to turn.
e.
Remove the dust protector from the cap (Gas models). Use the
proper size wrench to remove the cap from the regulator(All models).
f.
Follow the remaining instructions
provided in Fig. 3.
Tools
Required:
3/8", 1/2" and 5/8" Open End Wrench
_/_ ............
_.,.__
1/8" Wide Flat Blade Screwdriver
7mm Nutdriver
Pull up with finger
Left Glide
NOTE:
After replacing
the natural
gas to LP Orificesl
be sure to
keep the original
factory
installed
natural
gas orifices
for future
range conversion
back to natural
gas.
Push down with finger
pin 316417508 (0606)