Download Print this page

Kenmore 79070112705 Instructions For

Advertisement

Quick Links

INSTALLATION
AND SERVICE MUST BE PERFORMED
BY
A QUALIFIED INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
This conversion
kit must be installed by a qualified service technician
in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
Failure
to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation ofthis kit. The
installation is not proper and complete until the operation ofthe converted appliance is checked as specified in the
manufacturer's
instructions supplied with this kit.
Before proceeding with the conversion, shut offthe gas supply before disconnecting electrical power
to the range. Be sure both power supplies are off before installing the conversion kit. Failure to do so could cause
serious bodily injury.
Choose the combination of top burners that are featured
on your range to
determine the parts that are included in your kit.
Note: When burners are converted from Natural to LP the BTU rating is as
follows:
5,000 BTU* Natural Gas to 4,500 BTU* LP Gas
9,500 BTU* Natural Gas to 8,000 BTU* LP Gas
12,000 BTU* Natural Gas to 10,000 BTU* LP Gas
14,200 BTU* Natural Gas to 11,000 BTU* LP Gas
Surface Burner Orifice marked 0.68mm 4,500 BTU* (blue)
Surface Burner Orifice marked 0.89mm 8,000 BTU* (no color)
Surface Burner Orifice marked 0.95mm 10,000 BTU* (green)
Surface Burner Orifice marked 1.01mm 11,000 BTU* (red)
Installation Instructions
m
_
i/
.o:3
__
- =
==
' :E
316237907
0
1
0
316237906
3
2
4
316237905
1
1
0
316237904
0
0
0
316248100
1
1
1
A
m
1
1
1
1
1
,.O
o
m,,_ _
.i
1
2
0
1
1
*Note: For operation
at elevations
above 2000 ft., appliance
rating
shall be reduced at the rate of 4 percent for each 1000 ft. above sea
level.
NOTE: After
replacing the natural gas to Lp orifices,
be sure to
keep the original
factory
installed
natural gas orifices for future
range conversion
back to natural
gas.
How to Convert the Range for use with LP/
Propane Gas
1. Convert
the Pressure
Regulator
To access
the
gas
regulator,
remove
the
storage
drawer
or warmer
drawer. If equipped with a storage drawer, open and remove the drawer
completely.
For models
equipped
with
warmer
drawer,
follow
the
instructions
below to remove warmer
drawer.
a.
_!_
Electrical
Shock Hazard can occur and result in
serious
injury or death.
Disconnect
electrical
power to the range
before removing
the warmer
drawer for servicing.
b.
Locate glide lever on each side of drawer, pull up on the left glide lever
and push down on the right glide lever (See Figure 1).
c.
Pull the drawer away from the range (See Figure 2).
d.
Remove the regulator
access cover if equipped.
Do not remove
thePressure
Regulator
or allow
it to turn.
e.
Remove
the dust protector
from the cap.
Using a 5/8" wrench,
unscrew the cap from the pressure
regulator.
Do not remove
the
spring
from the regulator.
f.
Turn the cap over so the hollow end faces outward. Place the solid
end of the cap into the loop end of the dust protector (See Figure 3).
g.
Replace the cap on the regulator. The letters LP should be visible on
the exposed
end of the cap. Snap the dust protector
over
the
regulator
cap.
Tools Required:
3/8", 1/2" and 5/8" Open End Wrench
1/8" Wide Flat Blade Screwdriver
7mm Nutdriver
Pull up with finger
Left Glide
Push down with finger
FIGURE
1
P/N 316248100 (0306) REV C
1

Advertisement

loading

This manual is also suitable for:

790785316097907853060979078530608790796537067907136270579077433901 ... Show all