Receptacle Wiring:
Receptacle w iringshould bea minimum of 14gauge. U secopper w ireonly.
It is your responsibility to provide proper
and adequate receptacle wiring, installed by a qualified electrician.
Electrical
Requirements:
A 115 volt (103.5 minimum, 126.5 maximum), 60 Hertz, AC only, 15 ampere fused electrical supply is required. Atime
delay fuse or time delay circuit breaker is also required. A separate circuit, serving this appliance only, MUST be
provided.
Electrical
Connection:
Electrical grounding is required on this appliance.
Recommended
grounding
method:
For your personal safety, this appliance must be grounded.
This air conditioner includes a power supply cord with a
3-prong grounding plug. To minimize possible electrical shock
hazard:
cord must be plugged into a matching 3-prong grounding type
wall receptacle.
must be grounded in accordance with National Electrical
Code (ANSI/NFPA 70-latest version) and all local codes and
ordinances.
If a matching 3-prong grounding type wall receptacle is not available,
it is the responsibility of the consumer to have a properly grounded
3-prong wall receptacle installed by a qualified electrician.
3-Prong Grounding
Type Wall Rece
3-Prong
Grounding plug
Grounding prong
Power Supply
Cord
(6 feet long)
FIG. 1
Preparing
for Installation
Installation Tips
For wood-frame
casement windows:
It may be necessary to construct a frame, using at least
1" thick wood, with a 15-1/2" wide opening.
For brick or cement
building
construction:
It may be necessary to put a wood stool strip under air
conditioner, for mounting purposes as shown FIG. 2.
wood strip
Bottom Rail of
mounted on
air conditioner
top of inner sill
/
FIG. 2
Failure to adhere to the following precautions could result in personal injury and product damage.
• Because this unit weighs about 60 to 80 pounds, it is recommended that you have someone help you when
installing your new unit, and that you both use proper lifting techniques. Inspect the condition of the window
where unit will be installed. Be sure it will support the weight of the unit.
This appliance must be installed according to all applicable codes and ordinances.
Handle air conditioner with care. AVOID sharp metal fins on front and rear coils.
Make sure your air conditioner does not fall during installation.
Do not use water collected in the unit for drinking purposes. It is not sanitary.
Tools Required
Flat-head screwdriver
Carpenter's level
Fine tooth saw
Knife and scissors
Phillips-head screwdriver
• Tape measure
• Electric orhanddrill
• Pencil
® DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED IN THESE INSTRUCTIONS.