Three Conductor
Wire Connection
to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 8):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection
block (See page 2).
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply cord
to the center silver-colored
terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal,
black wires
connected to the left terminal) (see figure 8).
3. Replace the terminal cover and replace the screws.
Silver Colored Terminal
Red Wire
Four Conductor
Wire Connection
to Range
Where local codes does NOT permit connection
of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 9):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection
block (See page 2).
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance with
the ground screw, using the hole in the frame where
the ground strap was removed (see Figure 9).
4. Connect the neutral of the copper power supply cord
to the center silver-colored
terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
5. Replace the terminal cover and replace the screws.
Terminal Block
Silver Colored Terminal
Terminal
Block
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at This
Location.
To 240 V
Receptacle
Figure 8
1 1/8" (2,9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3,5 cm) Dia. Cord
Kit Hole.
Black
1 1/8" (2,9 cm)l
Dia. Direct
Connection
Hole. Punch
Out Knockout
1 3/8" (3,5 cm)
Dia. Cord Kit
Hole.
A User Supl
Strain-relief Must
Be Installed at
This Location
To 240 V Receptacle
NOTE: Be sure to remove the
supplied grounding strap.
Figure 9
6