Wiring
Figure 2-14
Multiple Camera Wiring
If you are operating the camera using 24 VAC and you are wiring more than one camera to the same
transformer:
Connect one side of the transformer to pin 1 of the 2-position terminal block on all modules.
Step 1
Connect the other side of the transformer to pin 2 of the terminal block on all modules.
Step 2
Note
Alarm and Relay Connector
Connect the alarm and relay wires to the supplied 4-pin connector (refer to
Step 1
Step 2
Attach the mating connector to the green connector on the side of the camera.
Cisco Video Surveillance 5010/5011 Indoor Fixed HD IP Dome Camera User Guide
2-12
24 VAC Connector
Failure to connect all modules identically might introduce video noise for some installations
24V~
Chapter 2
Installation
Figure
2-15).
OL-22669-01