Electrical Requirements; Installation Procedure - Maytag Jenn-Air Service Manual

Hide thumbs Also See for Jenn-Air:
Table of Contents

Advertisement

Electrical Requirements
1.
Provide an individual
120
volt,
60 HZ, branch circuit with ground for
the washer. This circuit must be
rated for
15
amperes or more.
2. Protect the washer1s electrical circuit
with a
15
ampere time delay fuse or
circuit breaker.
3. Install in accordance with National
Electrical Code and all local codes
and ordinances.
GROUNDING INSTRUCTIONS
The washer must be grounded. In the
event of a malfunction or breakdown,
grounding will reduce the risk of electri-
cal shock by providing a path of least
resistance for electrical current.
The washer is equipped with a power
supply cord which has a grounding
conductor and three-prong grounding
plug. For proper grounding, the three-
prong grounding plug must be plugged
into an appropriate three-prong
grounded receptacle or outlet (see the
following figure). The receptacle must
be properly installed and grounded in
accordance with the National Electrical
Code and all local codes and ordinances.
WARNING:
Improper connection of the
grounding conductor or the three-prong
grounding plug of the power supply
cord may result in an electrical shock
hazard.
If
there is any doubt as to
whether the washer is properly
grounded, have the installation checked
by a qualified electrician.
DO NOT MODIFY THE PLUG PROVIDED
WITH THE WASHER -If
the plug will not
fit the outlet,
have a proper outlet in-
stalled by a qualified technician.
INSTALLATION PROCEDURE
To remove the carton, cut along the
dotted line. Lift the carton and top cap
assembly up and clear of the washer.
NOTE:
Retain the corner posts for later
use.
1.
Untape and raise the washer lid;
remove the items shipped in the spin
basket. Save the literature for future
reference. Close and tape lid.
2. Place two (2) carton corner posts on
the floor to protect the unit and care-
fully lay the washer on its back on
top of the corner posts. DO NOT
LOWER OR RAISE THE WASHER BY
THE CONTROL PANEl.
Three-prong grounding plug
power supply cord. Approved
grounding type wall recep-
tacles, Pass & Seymour,
No.5261, Bryant No. 5261,
(Nema No.5 15 R) or equiva-
lent.
3. Remove the two hex-head screws
holding the wooden shipping base.
If the unit has a base made of poly-
propylene, only one hex-head screw
is used.
16007667
SECTION 1. INSTALLATION
1-2
©
1996 Maytag Corporation

Advertisement

Table of Contents
loading