Cable/Sensor error
Message on the display
Cable to * has faulty circuit. Please
check cable.
Cable to * has feedback current
without control current. Please
check cable.
All warnings associated with ** are
disabled. Use machine with
caution
*Cable error
Cylinder 1, valve
Cylinder 2, valve
Cylinder 3, valve
Cylinder 4, valve
Cylinder 5, valve
Outrigger proportional, valve
Left caterpillar track, valve
Right caterpillar track, valve
Rotation, valve
Tool, valve
Extra function 1, valve
Extra function 2, valve
Front left outrigger, valve
Front right outrigger, valve
Rear left outrigger, valve
Rear right outrigger, valve
Pressure, valve
**Sensor error
Temperature sensor
Pressure sensor
50 –
English
TROUBLESHOOTING
Indication on the machine
No indication on machine.
Effect on machine
Cause
functions
The cable has a short
circuit or broken
circuit.
The function using
the cable disabled.
The cable * have
feedback current
without being active.
All supervision
using the sensor is
Sensor ** is faulty.
disabled.
Possible action
Check cable.
Check the
sensor * and
cables to the
sensor.