Sony CDP-XE200 Service Manual page 2

Hide thumbs Also See for CDP-XE200:
Table of Contents

Advertisement

The laser component in this product
is capable of emitting radiation
exceeding the limit for Class 1.
The following caution label is located inside of the unit.
CAUTION
Use of controls or adjustments or performance of proce-
dures other than those specified herein may result in haz-
ardous radiation exposure.
Notes on Chip Component Replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be dam-
aged by heat.
MODEL IDENTIFICATION
– Back Panel –
CDP-XE200 :
Canadian Model
Australian Model
E Model
Chinese Model
UK Model
AEP, German, East European Model
CDP-XE300 :
AEP, German, East European Model
UK Model
Australian Model
Canadian Model
This appliance is classified
as a CLASS 1 LASER
product.
The CLASS 1 LASER
PRODUCT MARKING is
located on the rear exterior.
: 4-978-388-4π
: 4-978-388-5π
: 4-978-388-9π
: 4-979-971-0π
: 4-979-971-1π
: 4-979-971-2π
: 4-978-388-2π
: 4-978-388-3π
: 4-978-388-6π
: 4-978-388-8π
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a re-
turn to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digi-
tal multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The "limit" indication is 0.75
V, so analog meters must have an accurate low-voltage scale. The
Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM
that is suitable. Nearly all battery operated digital multimeters that
have a 2V AC range are suitable. (See Fig. A)
To Exposed Metal
Parts on Set
0.15µF
Fig. A. Using an AC voltmeter to check AC leakage.
– 2 –
AC
1.5k Ω
voltmeter
(0.75V)
Earth Ground

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdp-xe300

Table of Contents