Setting the Alarm Threshold Value

Configuring the Snapshot Clip Export Settings

MAXPRO NVR 3.1 Operator's Guide
Each event type supported in the NVR has a pre-defined Severity Level value associated to it.
When the event occurs, the value is compared with the value in the Alarm Severity
Threshold box in the Preferences dialog box. The alarm is triggered only when the Severity
Level value is greater than the Alarm Severity Threshold value. See Appendix B,
Alarm Types
section for default Event and Alarm types and their severity levels for Camera,
Recorder and Smart VMD.
For example, the alarm is triggered if the Severity Level for an event is 50 and the Alarm
Severity Threshold value is 40.
Note:
Severity level for alarms are displayed in the Alarm window, which is described in
the
Alarms
section.
To set the Alarm Severity Threshold value
1.
Click the Preferences option in the User menu,
appears. By default, the General Settings tab is selected.
2.
Under Server Level Settings, type an Alarm Severity Threshold.
Figure 3-15

Setting the Alarm Threshold

3.
Click Apply.
4.
Click OK to close the dialog box.
You can configure the time interval for the exported snapshot.
To configure the time interval for the exported snapshot
1.
Click the Preferences option in the User menu,
appears. By default, the General Settings tab is selected.
L O G G I N G O N A N D F A M I L I A R I Z A T I O N
Setting Preferences
. The Preferences dialog box
. The Preferences dialog box
Event and
59