9.13 High voltage power supply PCB ASSY
(1) Remove the FFC from the Guides of the Main frame L ASSY, and disconnect the
connector from the High voltage power supply PCB ASSY.
(2) Remove the Taptite bind B M4x12 screw.
(3) Release the Hooks to remove the High voltage power supply PCB ASSY.
Front cover sensor lever
High voltage power
supply PCB ASSY
Taptite bind B M4x12
Assembling Note:
• Assemble the Front cover sensor lever after assembling the High voltage power supply
PCB ASSY.
FFC
Guide
FFC
Hook
Hooks
Fig. 3-40
3-42
Guide
Main frame R ASSY
Confidential