LCD Message
UPS E10
Dependent Mode
SYSTEM Error E11
Fan Failure
SYSTEM Error E12
Cooling Failure
RAID Arrayx E14
Can't Mount
HDx Error E16
HDx Not Found
HDx Error E22
HDx Can't Mount
FailOver E27
LostBackupTarget
HDx Broken E30
Replace the DISK
Status
After you change settings or format a hard drive, the current status is displayed on the LCD.
LCD Message
SYSTEM I10
TOO HOT !
HDx Warning I11
Bad Sectors
Operation I12
DEGRADE MODE
RAID I13
ARRAYxFormatting
RAID I14
ARRAYx Checking
RAID I15
ARRAYx Scanning
RAID I16
ARRAYx Creating
RAID I17
ARRAYx Resyncing
Description
The TeraStation is running on the UPS
battery due to a power outage. The
system will now be shut down safely.
An error occurred in the fan speed.
A rise in the system temperature may
have exceeded the allowable safety value.
RAID array x cannot be mounted.
Unable to find hard drive x.
Unable to mount drive x.
Unable to find the backup TeraStation.
An error occurred, so hard drive x was
removed from the RAID array.
Description
System temperature is too high.
Drive x has too many bad sectors.
Operating in degraded mode.
Formatting RAID array x.
Checking RAID array x.
Examining the error status of RAID array
x.
Note: Transfer speeds are slower during
the examination process.
Creating RAID array x.
Resynchronizing RAID array x.
Note: Transfer speeds are slower during
resynchronization.
Corrective Action
Check that power is being supplied to the
UPS, and if there are no problems, turn on
the TeraStation.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
Do not place objects in the area around the
TeraStation. Also, move the TeraStation to a
cool location.
Run the RAID array disk check in Settings.
Hard drive x may be disconnected or may
have failed. After shutting down, reinstall
the hard drive.
Format the hard drive. After formatting,
if the error still appears after rebooting,
replace the hard drive. If the error is
displayed again, contact Buffalo technical
support for assistance.
In the main TeraStation's settings, navigate
to Backup - Failover to reconfigure the
backup TeraStation for failover.
Replace hard drive x.
Corrective Action
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
Replace hard drive x.
-
-
-
-
-
-