TROUBLESHOOTING

1. If the digital display is not illuminated:
• Check to see whether the Precise
Heat Mixing Bowl is plugged into an
outlet. If it is, check the fuse or circuit
breaker on the electrical circuit the
bowl is connected to and make sure
the circuit is closed.
2. If all the lights on the digital display
are flashing:
• The Precise Heat Mixing Bowl was
not in place when the Start/Cancel
button was pressed. Check that the
bowl is properly attached for your
model of Stand Mixer.
3. If the display shows "Er1" on the
digital display:
• The Precise Heat Mixing Bowl sensed
that an interruption occurred with
the Bowl Temperature Sensor (BTS).
Unplug the bowl and plug back in to
see if that will reset the unit.
If the display shows "Er2" on the
digital display:
• The BTS has sensed an abnormal
temperature. Unplug the Precise
Heat Mixing Bowl and allow it to
be brought to room temperature
before plugging it back in.
4. I f the Temperature indicator flashes
quickly 3 times when selecting the desired
Temperature setting:
• The dial was rotated past the maximum
temperature setting. Turn dial the
other way to reduce the Temperature
selection.
If the problem cannot be corrected using the
steps above, see the "Warranty and service"
section. Do not return the Precise Heat
Mixing Bowl to the retailer; retailers do
not provide service.